BuyLog Flippingbook NOV 2024

8-97

LOW VOLTAGE POWER & INSULATED CASE CIRCUIT BREAKERS, BUYLOG SECTION 8

— EntelliGuard ™ G low voltage power circuit breakers EntelliGuard ™ G cassettes nomenclature

Digit 5 Cassette AIC Rating Interrupting Rating Tier ANSI/UL1066 Devices, LVPCB

Envelope 1

Envelope 2

Envelope 3

1/2S Withstand

Override No. 1

Override WI

400 1200

400 2000

400 3200

4000 5000

Code

254V 580V 635V

HSIOC

Code

3200

3200

S

65,000 65,000 50,000 50,000 65,000 65,000 65,000 65,000 85,000 85,000 65,000 65,000 100,000 100,000 65,000 65,000 85,000 85,000 85,000 85,000 100,000 100,000 100,000 85,000 100,000 100,000 100,000 100,000

50,000 49,000 53,500

S

• • •

N H

None None

None

N H

65,000 63,700 69,500 65,000 63,700 69,500

P 2

P E

• •

E

None None

None

• • •

M

85,000 83,800 90,950

M

• •

B L

None None

None

B

150,000 150,000 100,000 100,000 100,000 98,000 107,000 L

Interrupting Rating Tier UL489 Devices ICCB

Envelope 1

Envelope 2

Envelope 3

1/2S Withstand

Override No. 1

Override WI

400 1200

400 2000

2500 3000

400 3000

4000 6000

Code

240V 480V 600V

HSIOC

Code

3000

S

65,000 65,000 50,000 42,000 65,000 65,000 65,000 42,000 85,000 85,000 65,000 50,000 100,000 100,000 100,000 65,000 150,000 150,000 100,000 85,000 100,000 100,000 65,000 50,000

42,000 42,000 50,000 65,000 85,000 50,000

N/A N/A N/A N/A N/A N/A

44,940 44,940 53,500 69,550 90,950 50,000

S

• •

• •

N H M

N H M

• •

L

L P

P 2

ANSI Non-Automatic Switches

Envelope 1 800-2000

Envelope 2 800-3200

Envelope 3 3200-5000

30 Cycle Withstand Ratings

Code

254V 580V 635V 42,000 42,000 42,000 65,000 65,000 65,000 100,000 100,000 100,000

Code

N M

N M

Note: Non-automatic switches are provided with no internal sensing or tripping mechanism and cannot be applied above their respective withstand levels. If a non-automatic device is required at ratings above the available switches is required, it is recommended that a circuit breaker set with maximum setting be employed using external control or protection as required by the application.

B

B

UL489 Non-Automatic Switches

Envelope 1 800-2000

Envelope 2 800-3000

Envelope 3 3000-6000

Code

240V 480V 600V 42,000 42,000 42,000 65,000 65,000 65,000 150,000 150,000 100,000

Code

N M

N M

B

B

Digit 6 Number of Poles Devices Series/ Line

Digit 7 Shutters Shutters with Locks

Code

Code

OEM Cassette - 3 Pole OEM Cassette - 4 Pole

2 5

Shutter and Shutter Lock - Factory Installed

S X

None

ABB Equipment Cassette - 3 Pole 1 7 1 ABB Equipment cassette designed specifically for AKD20 Switchgear. These cassettes are NOT available for OEMs. 2 P frame available as 3-pole only

Product Number GCPS1R GCPS2R GCKRKR GCR0NR GSDWTR GSDWSR

Loose Cassette Parts- Field Installed

Carriage Position Switch - 1NO/1NC Carriage Position Switch-2NO/2NC 1 Kirk Key Interlock Cam for Cassette 1 Ronis Key Interlock Cam for Cassette

Secondary Disconnect Block B, 39 Pole-Top Mounted Secondary Disconnect Block B, 39 Pole-Side Mounted

Secondary Disconnect Block B is required when: 1. Any "ZONE SELECTIVE INTERLOCKING" options are selected in breaker/trip unit Catalog Digit 18. 2. Any "ADVANCED FEATURES" are selected in breaker/trip unit Catalog Digit 19. 3. A COIL SIGNALING CONTACT OPTION is selected, Digit 12. 4. A READY TO CLOSE signal via the trip unit is selected, Digit 13. 5. Any of the following OPTIONAL Aux. Contact Switches are selected in Digit 12: – 8NO/NC POWER RATED

– 3NO/NC POWER RATED + 2NO/NC Hi-Fi – 4NO/NC POWER RATED + 4NO/NC Hi-Fi

Made with FlippingBook - Online Brochure Maker