BuyLog Flippingbook MAR 2026

20-5

SURGE PROTECTION DEVICES, BUYLOG SECTION 20

— ReliaGear Surge Protective Device RGWMSP

The core suppression system includes proprietary Metal Oxide Varistors (MOVs) for surge energy diversion and metal film capacitors for filtering low-level transient voltages and electrical noise. The design is UL Listed, suitable for all NEC compliant installations.

Standards: • UL 1449 5th Ed. – Listed, —Mil-Std-220C

• UL 1283 Listed EMI/RFI Filter—ANSI/NFPA 70 (Art. 242) • UL 96A – Meets SPD criteria—ANSI/IEEE C62.41 & .45 • cUL Listed to UL 1449 & CSA C22.2—ANSI/IEEE C62.62 & .7

Electrical characteristics

80 kA per mode / 160 kA per phase 150 kA per mode / 300 kA per phase 225 kA per mode / 450 kA per phase 300 kA per mode / 600 kA per phase

Maximum surge current rating

The ReliaGear® RGWMSP Series offers robust surge protection with an emphasis on performance, safe operation, and user-friendly diagnostics. ReliaGear® RGWMSP Series SPDs are engineered with smart thermal disconnecting technology that safely removes over stressed components before harmful external effects arise. This preventive approach enhances safety and avoids nuisance from OCPD tripping or thermal events. Part number 120S 240 / 120 1-phase, 3-wire + ground RGWMSP120S XX**&& 120Y 208Y / 120 3-phase, 4-wire + ground RGWMSP120Y XX**&& 240D 240 Delta 3-phase, 3-wire + ground RGWMSP240D XX**&& 240H 240 / 120 Hi-Leg Delta 3-phase, 4-wire + ground RGWMSP240H XX**&& 220Y 380Y / 220 3-phase, 4-wire + ground RGWMSP220Y XX**&& 240Y 415Y / 240 3-phase, 4-wire + ground RGWMSP240Y XX**&& 277Y 480Y / 277 3-phase, 4-wire + ground RGWMSP277Y XX**&& 480D 480 Delta 3-phase, 3-wire + ground RGWMSP480D XX**&& 600D 600 Delta 3-phase, 3-wire + ground RGWMSP600D XX**&& Desired kA XX Code 80 kA/mode 08 150kA/mode 15 Voltage Configuration

Nominal discharge current rating (In) Operating frequency Surge life (IEEE C62.41 - C3 10 kA ) Modes of protection Fault rating (SCCR)

20 kA

50–60 Hz

≥5,000 impulses

All modes (L-N, L-G, N-G, L-L)

200 kAIC

Tri-Color LED indicators per phase: Green LED normal operation, SPD componentry is compromised, Orange Service indicator alarm. Rotatable Color View LCD display. Phase loss indication. N-G Voltage Detection > 20V detected. Audible alarm w/ silence option.Dry Contacts: Remote dry (volt-free) relay contacts rated at (<2 A, 250Vac / 220Vdc)

Standard monitoring

EMI / RFI filter attenuation Maximum attenuation frequency Mechanical characteristics Weight

-61 dB at 100.2 kHz

Varies and depends on enclosure type

Enclosure type

Varies on option chosen

Service entrance equipment, primary distribution equipment

Installation location

Mounting method

Surface mount, 4-point mounting brackets -40 °F to 149 °F (-40 °C to 65 °C) < 13,000 ft (datasheet value based on C&C calculations)

Operating temperature

22 - O nly available on RGWMSP models with type 4 enclosure 30 - O nly available on RGWMSP models with type 4 enclosure

225 kA/mode

Altitude

Individually fused thermally protected MOV technology

Product design

Regulations and certifications UL 1449 5th edition

300 kA/mode

Type 1 / Type 2 Type 1 / Type 2 Type 1 / Type 2

cUL, CSA C22.2

Type

** Code

UL 1283 UL 96A

Type 2 SPD Type 1 SPD Enclosure

T2 T1

Type 2

cUL Listed to UL 1449 & CSA C22.2—ANSI/IEEE C62.62 & .72

&& Code

Yes

NEMA 1

1

NEMA 1 with Disconnect

1D 4D XD

IEC 61643-11

Yes

NEMA 4 with Disconnect (Painted Steel) NEMA 4X stainless steel with Disconnect

Listed by

UL

Made with FlippingBook - Online magazine maker