LOAD CENTERS, METER COMBOS, SINGLE SOCKET METERING, RESIDENTIAL CIRCUIT BREAKERS, AND SMART PANEL, BUYLOG SECTION 1
1-27
— ReliaHome meter combos
Dual main circuit breaker, ringless, Class 320
Max branch circuit breaker circuits
Max branch circuit breaker spaces
Interrupting rating Front type Bypass type UL incoming Socket layout type
Main ampere rating
Ordering code
300
8 8 0 0 0 8 8 8
16 16
22 22 22 22 22 22 22 22 22
Semiflush
Lever Lever Lever Lever Lever Lever Lever Lever Lever
OH/UG
Side by Side Side by Side Side by Side Side by Side Side by Side Side by Side Side by Side Side by Side Side by Side
TSDR830CFCUGP 3,5 TSDR830USCU 2,3,5
Surface
UG UG UG UG UG
320 400
0 0 0
Semiflush
TSDR032UFCU 2
Flush
TSDR040UFCUAEP 2,4 TSDR040UFCU 2,5 TSDR840UFCU 2,5 TSDR840CFCUGP 3,5 TSDR840UFCUAEP 2,4
Semiflush
16 16 16 40
Surface Surface
OH/UG
Flush
UG UG
24
Semiflush
TM2440RMRS 1,2
*Note: Please review your local utility specs to determine the SKU to fit your local needs.
1 For semi-flush applications, order surface enclosure load center and field installed kit, Ordering code SF400. 2 Stud provisions only provided. Line and neutral lugs are not included. To be provided by others. 3 Georgia Power Approved
4 AEP Approved 5 MEG Approved
Application data
Equipment ground kit (order separately if additional grounds are required) TGL2, TGL4, or TGL8 order separately
Enclosure depth (in inches)
Enclosure height (in inches)
Enclosure width (in inches)
Factory installed service disconnect A2N150CTL-2SB
Secondary service disconnect*
Main wire size (AWG/kcmil) Cu-Al (2) 250 MCM per phase & neutral (lugs included)
Box number
Ordering code
TSDR830CFCUGP
R33
30-1/4
33 6-3/32
Available circuit breakers: 1,2,5,6 Comes with factory installed A2N150CTL-4SB. Available circuit breakers: 1,2,5,6 Comes with factory installed A2N150CTL-4SB. Available circuit breakers: 1,2,3,4,5,6,7,8 Available circuit breakers: 1,2,3,4,5,6,7,8 Available circuit breakers: 1,2,3,4,5,6,7,8 Available circuit breakers: 1,2,3,4,5,6,7,8 Comes with factory installed A2N2000CTL-4SB. Available circuit breakers: 1,2,3,4,5,6,7,8 Available circuit breakers: 1,2,3,4,5,6,7,8 THHQL21125
Studs only
TGL2, TGL4, or TGL8 order separately
TSDR830USCU
R33
30-1/4
33 6-3/32
A2N150CTL-2SB
TSDR032UFCU
R33
30-1/4
33 6-3/32
A2N200CTL-2SB
Studs only
TGL2, TGL4, or TGL8 order separately TGL2, TGL4, or TGL8 order separately TGL2, TGL4, or TGL8 order separately TGL2, TGL4, or TGL8 order separately TGL2, TGL4, or TGL8 order separately
TSDR040UFCUAEP
R33
30-1/4
33 6-3/32
A2N200CTL-4SB
Studs only
TSDR040UFCU
R33
30-1/4
33 6-3/32
A2N200CTL-4SB
Studs only
TSDR840UFCU
R33
30-1/4
33 6-3/32
A2N200CTL-2SB
Studs only
(2) 250 MCM per phase & neutral (lugs included)
TSDR840CFCUGP
R33
30-1/4
33 6-3/32
A2N200CTL-2SB
TSDR840UFCUAEP
R33
30-1/4
33 6-3/32
A2N200CTL-2SB
Studs only
TGL2, TGL4, or TGL8 order separately
TM2440RMRS TGL2, TGL4, or TGL8 order separately NOTE: The combined amperage of the two mains cannot exceed the main amperage rating of the SKU. IE: If your main is 300A then your two disconnects cannot exceed 300A. R24 30-1/4 40 6 A2N200CTL-2SB Studs only
* Secondary service disconnect: 1 A2A125CTL-4SB 2 A2A150CTL-4SB 3 A2A175CTL-4SB 4 A2A200CTL-4SB 5 A2N125CTL-4SB 6 A2N150CTL-4SB 7 A2N175CTL-4SB 8 A2N200CTL-4SB
NOTE: Circuit breakers must be ordered separately. Click here.