BuyLog Flippingbook MAY 2025

LOAD CENTERS, METER COMBOS, SINGLE SOCKET METERING, RESIDENTIAL CIRCUIT BREAKERS, AND SMART PANEL, BUYLOG SECTION 1

1-27

— ReliaHome meter combos

Dual main circuit breaker, ringless, Class 320

Max branch circuit breaker circuits

Max branch circuit breaker spaces

Interrupting rating Front type Bypass type UL incoming Socket layout type

Main ampere rating

Ordering code

300

8 8 0 0 0 8 8 8

16 16

22 22 22 22 22 22 22 22 22

Semiflush

Lever Lever Lever Lever Lever Lever Lever Lever Lever

OH/UG

Side by Side Side by Side Side by Side Side by Side Side by Side Side by Side Side by Side Side by Side Side by Side

TSDR830CFCUGP 3,5 TSDR830USCU 2,3,5

Surface

UG UG UG UG UG

320 400

0 0 0

Semiflush

TSDR032UFCU 2

Flush

TSDR040UFCUAEP 2,4 TSDR040UFCU 2,5 TSDR840UFCU 2,5 TSDR840CFCUGP 3,5 TSDR840UFCUAEP 2,4

Semiflush

16 16 16 40

Surface Surface

OH/UG

Flush

UG UG

24

Semiflush

TM2440RMRS 1,2

*Note: Please review your local utility specs to determine the SKU to fit your local needs.

1 For semi-flush applications, order surface enclosure load center and field installed kit, Ordering code SF400. 2 Stud provisions only provided. Line and neutral lugs are not included. To be provided by others. 3 Georgia Power Approved

4 AEP Approved 5 MEG Approved

Application data

Equipment ground kit (order separately if additional grounds are required) TGL2, TGL4, or TGL8 order separately

Enclosure depth (in inches)

Enclosure height (in inches)

Enclosure width (in inches)

Factory installed service disconnect A2N150CTL-2SB

Secondary service disconnect*

Main wire size (AWG/kcmil) Cu-Al (2) 250 MCM per phase & neutral (lugs included)

Box number

Ordering code

TSDR830CFCUGP

R33

30-1/4

33 6-3/32

Available circuit breakers: 1,2,5,6 Comes with factory installed A2N150CTL-4SB. Available circuit breakers: 1,2,5,6 Comes with factory installed A2N150CTL-4SB. Available circuit breakers: 1,2,3,4,5,6,7,8 Available circuit breakers: 1,2,3,4,5,6,7,8 Available circuit breakers: 1,2,3,4,5,6,7,8 Available circuit breakers: 1,2,3,4,5,6,7,8 Comes with factory installed A2N2000CTL-4SB. Available circuit breakers: 1,2,3,4,5,6,7,8 Available circuit breakers: 1,2,3,4,5,6,7,8 THHQL21125

Studs only

TGL2, TGL4, or TGL8 order separately

TSDR830USCU

R33

30-1/4

33 6-3/32

A2N150CTL-2SB

TSDR032UFCU

R33

30-1/4

33 6-3/32

A2N200CTL-2SB

Studs only

TGL2, TGL4, or TGL8 order separately TGL2, TGL4, or TGL8 order separately TGL2, TGL4, or TGL8 order separately TGL2, TGL4, or TGL8 order separately TGL2, TGL4, or TGL8 order separately

TSDR040UFCUAEP

R33

30-1/4

33 6-3/32

A2N200CTL-4SB

Studs only

TSDR040UFCU

R33

30-1/4

33 6-3/32

A2N200CTL-4SB

Studs only

TSDR840UFCU

R33

30-1/4

33 6-3/32

A2N200CTL-2SB

Studs only

(2) 250 MCM per phase & neutral (lugs included)

TSDR840CFCUGP

R33

30-1/4

33 6-3/32

A2N200CTL-2SB

TSDR840UFCUAEP

R33

30-1/4

33 6-3/32

A2N200CTL-2SB

Studs only

TGL2, TGL4, or TGL8 order separately

TM2440RMRS TGL2, TGL4, or TGL8 order separately NOTE: The combined amperage of the two mains cannot exceed the main amperage rating of the SKU. IE: If your main is 300A then your two disconnects cannot exceed 300A. R24 30-1/4 40 6 A2N200CTL-2SB Studs only

* Secondary service disconnect: 1 A2A125CTL-4SB 2 A2A150CTL-4SB 3 A2A175CTL-4SB 4 A2A200CTL-4SB 5 A2N125CTL-4SB 6 A2N150CTL-4SB 7 A2N175CTL-4SB 8 A2N200CTL-4SB

NOTE: Circuit breakers must be ordered separately. Click here.

Made with FlippingBook - professional solution for displaying marketing and sales documents online