BuyLog Flippingbook FEB 2025
LOW VOLTAGE POWER & INSULATED CASE CIRCUIT BREAKERS, BUYLOG SECTION 8
8-118
— Trip units Product number nomenclature system
Digit 6 and 7 Overcurrent Protection Package Type
Over Current (OC) Protection Package LSI (S, switchable) (I, switchable ANSI only) LSIG (S, switchable) (I, switchable ANSI only)
Code
L3 L4 L5 L6 L7 L8 L9 LC LD LE LF LG LH LK
LSIGA (S, switchable) (I, switchable ANSI only) (G, Alarm Only)
Standard Range Instantaneous
LSIC (S, switchable) (I, switchable ANSI only)
LSICA (S, switchable) (I, switchable ANSI only) (C, Alarm Only) LSIGDA 1 (S, G, A switchable) (I, switchable ANSI only) LSIGCDA 1 (S, G, C, A all switchable) (I, switchable ANSI only)
EntelliGuard ™ G ANSI/UL OC Protection
LSH (S, switchable) (I, switchable ANSI only) LSHG (S, switchable) (I, switchable ANSI only)
LSHGA (S, switchable) (I, switchable ANSI only) (G, Alarm Only)
Extended Range Adjustable Instantaneous
LSHC (S, switchable) (I, switchable ANSI only)
LSHCA (S, switchable) (I, switchable ANSI only) (C, Alarm Only) LSHGDA 1 (S, G, A switchable) (I, switchable ANSI only) LSHGCDA 1 (S, G, C, A all switchable) (I, switchable ANSI only)
1 Function Combination is NOT UL Listed
NOTES: L = Long Time (L, I 2 T) + Fuse Settings (I 4 T) (Fuse settings are now standard on all EntelliGuard ™ Trip Units) S = Short Time (Switchable if Instantaneous (I) protection is enabled) I = Standard Range Adjustable Instantaneous, (IOC, 2x-15x)
H = Extended Range Adjustable Instantaneous, (IOC, 2x-30x), Only for ANSI EntelliGuard ™ G G = Ground Fault Protection (GFP, 3-wire or 4-wire, internal summing) Trip and Alarm C = External CT for ground fault detection (AKD20 application: input from external summing CTs, used for multiple source ground fault dectection.
OEM Application: Zero Sequence Input of 1A = 100%) D = Defeatable/Switchable Ground Fault, NOT UL Listed A = Ground Fault, External Ground Fault, Alarm only GA = Ground Fault Alarm Only CA = External Ground Fault Alarm Only GDA, GCDA = Ground Fault Trip and Ground Fault Alarm (all switchable, Not UL Listed)
Digit 8 Zone Selective Interlocking (ZSI) Zone Selective Interlocking
Digit 10 Manual/Auto Trip Reset Manual/Auto Trip Reset
Code
Code
ZSI, Short time and GF; user selectable Z+IOC or HIOC ZSI; user selectable
Z T
Manual Lockout
M
Auto Reset/Reclose
A
Blank/none X ZSI selections require Secondary Disconnect Block B and 24Vdc control power. NOTE: Option X is the only valid item when a Switch is selected in Digit 2.
Auto/Manual Lockout (Selectable) 2 None (Defaults to Auto Reset/Reclose) X Note: When Bell Alarm with Lockout is selected on the EntelliGuard ™ G Circuit Breaker, then Code M must be selected X is only valid on ABB Legacy Circuit Breakers and Conversion Kits M is valid on EntelliGuard ™ G Breakers when a Bell Alarm is selected A is valid on EntelliGuard ™ G Breakers when a Bell Alarm is not selected 2 S is IEC Only S 2
Digit 9 Advanced Features and Communications Advanced Features and Communications
Code
Reduced Energy Let-Through (RELT)
1 2 3 4 5
Modbus Protocol + RELT Profibus Protocol + RELT
Digit 11 Factory or Field Installed Manual/Auto Trip Reset Factory Installed Trip Unit (Original) Replacement Trip Unit (shipped loose)
Code
Monitoring + RELT, NO Communication Monitoring + Relay Package + RELT
F R
Monitoring + Data Acquisition, Modbus Protocol + RELT 6 Monitoring + Data Acquisition, Profibus Protocol + RELT 7 Monitoring + Data Acquisition + Relay Package, Modbus + RELT 8 Monitoring + Data Acquisition + Relay Package, Profibus + RELT 9 NONE X NOTES: All Advanced Feature selections require Secondary Disconnect Block B and 24Vdc control power
RELT = Reduced Energy Let Through Monitoring = Advanced Metering Data Acquisition = Waveform Capture and Harmonic Analysis
Made with FlippingBook Online newsletter creator