BuyLog Flippingbook FEB 2025

15-33

MOTOR CONTROL CENTERS - LOW VOLTAGE, BUYLOG SECTION 15

— 8000 line LV MCC replacement starter program

Starter product number

M

1

2

2

3

4

5

5

6

7

8

8

8

9

10

10

4: Control power

5: Pilot devices (continued)

Product number digits

Standard control power transformer (CPT) ratings are adequate to handle the starter-coil current and three pilot lights. If additional burdens are expected, larger transformers should be specified from among those shown in the first table below. From the second table below, select the control power desired.

Pilot device

FVNR starter type (continued) OFF/ON SW. OFF/ON SW. RED LGT STD

GN UB UP UC UQ NN QE QR QF QS QG QT CN QB QP QC QQ DN RB RP RC RQ SF SS SG ST EN SB SP SC SQ FN TL TP TC TQ NN

Starter type and size CPT Min. VA

Oversize VA

OFF/ON SW. RED LGT PTT OFF/ON SW. R/G LGT STD OFF/ON SW. R/G LGT PTT

All size 1 All size 2 All size 3 All size 4

60

150

150 300 300

– – –

FVR starter type NONE - Blank Pilot Device Bracket Provided

Note: For 380V units, all CPTs rated at 250VA.

RED/GREEN LGT STD RED/GREEN LGT PTT RED/AMBER LGT STD RED/AMBER LGT PTT

Product number digit

Starter size

Control power (120 Vac)¹

R/A/G LGT STD R/A/G LGT PTT

1 2 3 4 • • • •

Std. CPT

1 5

Common/Separate source • • • • ¹At 380V 50Hz, control volts will be 110Vac; at 575V 60Hz, control volts will be 115Vac.

FWD/REV/STOP PB

FWD/REV/STOP PB R/A LGT STD FWD/REV/STOP PB R/A LGT PTT FWD/REV/STOP PB R/G/A LGT STD FWD/REV/STOP PB R/G/A LGT PTT FWD/OFF/REV SW RED LGT STD FWD/OFF/REV SW RED LGT PTT FWD/OFF/REV SW R/G LGT STD FWD/OFF/REV SW R/G LGT PTT FWD/OFF/REV SW

5: Pilot devices Select pilot devices desired by starter type.

Product number digits

Pilot device

FVNR starter type NONE - Blank Pilot Device Bracket Provided

2S1W and 2S2W starter type NONE - Blank Pilot Device Bracket Provided

NN OE OF OS OT AN OB OP OC OQ OD OR BN PB PP PC PQ

RED LGT STD

RED/AMBER LGT STD RED/AMBER LGT PTT

RED LGT PUSH-TO-TEST (PTT)

RED/GREEN LGT STD RED/GREEN LGT PTT

R/A/G LGT STD R/A/G LGT PTT

HAND/OFF/AUTO (H/O/A) SW.

FAST/SLOW/STOP PB

H/O/A SW. RED LGT STD H/O/A SW. RED LGT PTT H/O/A SW. R/G LGT STD H/O/A SW. R/G LGT PTT

FAST/SLOW/STOP PB R/A LGT STD FAST/SLOW/STOP PB R/A LGT PTT FAST/SLOW/STOP PB R/A/G LGT STD FAST/SLOW/STOP PB R/A/G LGT PTT FAST/SLOW/OFF/AUTO (F/S/O/A) SW

H/O/A SW. STOP/START PB RED LGT STD H/O/A SW. STOP/START PB RED LGT PTT

F/S/O/A SW R/A LGT STD F/S/O/A SW R/A LGT PTT F/S/O/A SW R/A/G LGT STD F/S/O/A SW R/A/G LGT PTT

STOP/START PB

STOP/START PB RED LGT STD STOP/START PB RED LGT PTT STOP/START PB R/G LGT STD STOP/START PB R/G LGT PTT

Note: Pricing available through empower.

Made with FlippingBook Online newsletter creator