15-33
MOTOR CONTROL CENTERS - LOW VOLTAGE, BUYLOG SECTION 15
— 8000 line LV MCC replacement starter program
Starter product number
M
1
2
2
3
4
5
5
6
7
8
8
8
9
10
10
4: Control power
5: Pilot devices (continued)
Product number digits
Standard control power transformer (CPT) ratings are adequate to handle the starter-coil current and three pilot lights. If additional burdens are expected, larger transformers should be specified from among those shown in the first table below. From the second table below, select the control power desired.
Pilot device
FVNR starter type (continued) OFF/ON SW. OFF/ON SW. RED LGT STD
GN UB UP UC UQ NN QE QR QF QS QG QT CN QB QP QC QQ DN RB RP RC RQ SF SS SG ST EN SB SP SC SQ FN TL TP TC TQ NN
Starter type and size CPT Min. VA
Oversize VA
OFF/ON SW. RED LGT PTT OFF/ON SW. R/G LGT STD OFF/ON SW. R/G LGT PTT
All size 1 All size 2 All size 3 All size 4
60
150
150 300 300
– – –
FVR starter type NONE - Blank Pilot Device Bracket Provided
Note: For 380V units, all CPTs rated at 250VA.
RED/GREEN LGT STD RED/GREEN LGT PTT RED/AMBER LGT STD RED/AMBER LGT PTT
Product number digit
Starter size
Control power (120 Vac)¹
R/A/G LGT STD R/A/G LGT PTT
1 2 3 4 • • • •
Std. CPT
1 5
Common/Separate source • • • • ¹At 380V 50Hz, control volts will be 110Vac; at 575V 60Hz, control volts will be 115Vac.
FWD/REV/STOP PB
FWD/REV/STOP PB R/A LGT STD FWD/REV/STOP PB R/A LGT PTT FWD/REV/STOP PB R/G/A LGT STD FWD/REV/STOP PB R/G/A LGT PTT FWD/OFF/REV SW RED LGT STD FWD/OFF/REV SW RED LGT PTT FWD/OFF/REV SW R/G LGT STD FWD/OFF/REV SW R/G LGT PTT FWD/OFF/REV SW
5: Pilot devices Select pilot devices desired by starter type.
Product number digits
Pilot device
FVNR starter type NONE - Blank Pilot Device Bracket Provided
2S1W and 2S2W starter type NONE - Blank Pilot Device Bracket Provided
NN OE OF OS OT AN OB OP OC OQ OD OR BN PB PP PC PQ
RED LGT STD
RED/AMBER LGT STD RED/AMBER LGT PTT
RED LGT PUSH-TO-TEST (PTT)
RED/GREEN LGT STD RED/GREEN LGT PTT
R/A/G LGT STD R/A/G LGT PTT
HAND/OFF/AUTO (H/O/A) SW.
FAST/SLOW/STOP PB
H/O/A SW. RED LGT STD H/O/A SW. RED LGT PTT H/O/A SW. R/G LGT STD H/O/A SW. R/G LGT PTT
FAST/SLOW/STOP PB R/A LGT STD FAST/SLOW/STOP PB R/A LGT PTT FAST/SLOW/STOP PB R/A/G LGT STD FAST/SLOW/STOP PB R/A/G LGT PTT FAST/SLOW/OFF/AUTO (F/S/O/A) SW
H/O/A SW. STOP/START PB RED LGT STD H/O/A SW. STOP/START PB RED LGT PTT
F/S/O/A SW R/A LGT STD F/S/O/A SW R/A LGT PTT F/S/O/A SW R/A/G LGT STD F/S/O/A SW R/A/G LGT PTT
STOP/START PB
STOP/START PB RED LGT STD STOP/START PB RED LGT PTT STOP/START PB R/G LGT STD STOP/START PB R/G LGT PTT
Note: Pricing available through empower.