OEM Control Panel Products Highlights

Product highlights ABB Low voltage products for control panels and more

© 2025 ABB. All rights reserved.

— ABB Low voltage products for control panels and more

Table of contents 01. Molded case and miniature circuit breakers 02. Other circuit protection 03. Surge protective devices 04. Power distribution systems 05. Automatic transfer switches 06. Disconnect switches 07. IEC-style contactors, overload 08. Control and protective relays 09. Operator interface and signaling devices 10. Softstarters 11. Machine safety 12. Enclosures 13. Appendix

relays and manual motor starters

This booklet highlights key ABB low-voltage products suitable for OEM and control panel applications

Note: Ratings listed in this booklet are UL ratings.

IEC ratings are available online at www.abb.com or in each product’s specific technical catalog.

01

Molded case and miniature circuit breakers

SACE® Tmax® XT

F e b r u a r y 2

— SACE® Tmax® XT Break new ground

— SACE® Tmax® XT Break new ground

PRODUCT DESCRIPTION

The SACE® Tmax® XT UL 489 molded case circuit breaker (MCCB) range helps ensure extreme performance and protection features up to 1200 amps. Tmax XT MCCBs are designed to maximize ease of use, integration and connectivity, and are built to deliver safety, reliability and quality.

— SACE® Tmax® XT Break new ground

FEATURES AND BENEFITS

An efficient product that prevents overdesign

Advanced features to cover every need • 1% Accuracy embedded power metering • Embedded software to handle load shedding, automatic transfer switching, and microgrid applications • Power quality, voltage, and frequency measurement and alarms • Adaptive protections for complex systems • I/O and temperature monitoring Easy integration into building and automation systems • 110+ Native-spoken communication protocols make integration easier • IEC61850 capability allows MV and LV to speak the same language

• XT1 and XT3 allow you to buy 480V when you need 480V, and save versus 600V rated breakers • Thermal Magnetic trip units are offered up to 800A – offering savings versus electronic trip breakers • Upgrade trip units in the field to support future plans, and use exactly the protections you need without buying ones you don’t with Ekip Touch trip units A global platform • UL products rated for CSA and IEC • CCC for China available • Serviceability across the globe

— SACE® Tmax® XT Break new ground

XT1

XT2

XT3

XT4

Frame size (A)

125

125

225

250

240 V AC 50, 65, 100 65, 100, 150, 200

50, 65

65, 100, 150, 200 25, 35, 65, 100, 150, 200

Interrupt rating (kA)

25, 35, 65, 100, 150, 200

480 V AC 25, 35, 65

25, 35

600 V AC

– 18, 22, 25, 35, 42

– 18, 22, 25, 50, 65, 100

TMF

TMA

Trip units

Ekip Dip

Ekip Touch

VISIT PRODUCT PAGE

— SACE® Tmax® XT Break new ground

XT5

XT6

XT7

Frame size (A)

400, 600

800

800, 1000, 1200

240 V AC

65, 100, 150, 200

65, 100, 200

65, 100, 200

Interrupt rating (kA)

480 V AC 35, 50, 65, 100, 150, 200

35, 50, 65

50, 65, 100

600 V AC

18, 25, 35, 65, 100

20, 25, 35

25, 50, 65

TMF

TMA

Trip units

Ekip Dip

Ekip Touch

VISIT PRODUCT PAGE

— SACE® Tmax® XT Break new ground

MOUNTING OPTIONS

Fixed mount

Plug-in

Drawout

ReliaGear Tmax XT

VISIT PRODUCT PAGE

SACE® Tmax® PV

F e b r u a r y 2

— SACE® Tmax® PV

Adaptability, versatility and complete freedom

— SACE® Tmax® PV

Adaptability, versatility and complete freedom

PRODUCT DESCRIPTION

The SACE® Tmax® PV range of molded-case circuit breakers and switch-disconnectors for photovoltaic application offers an increasingly comprehensive, leading-edge solution that anticipates the market trends. As a global leader in this area, ABB continues to update its range by proposing a series of products to UL and IEC Standards for protecting and isolating your systems up to 1500V DC and 800V AC, thereby anticipating the most advanced PV plant construction trends. The goal is to enhance the energy efficiency and running economy of the photovoltaic plants due to a decisive increase in operating voltage in both the DC and AC sections.

— SACE® Tmax® PV

Adaptability, versatility and complete freedom

FEATURES AND BENEFITS

Accelerated projects • Enables quicker installation and lower wiring costs for the most advanced photovoltaic plant architectures, with significant time savings for utilities, engineers and panel builders

Easy installation • The expansive portfolio

of accessories includes mandatory connection jumpers for UL versions. The jumper kits allow simple installation with maximum safety • Perfectly integrated into the wide range of electrical and mechanical accessories already available for SACE Tmax T

Energy efficiency • Boosts efficiency with higher voltages for AC and DC systems

— SACE® Tmax® PV

Adaptability, versatility and complete freedom

Circuit breakers up to 1500VDC

T4N/PV

T5N/PV

T6N/PV

T4N/PV-E

Frame size

200A

400A

600-800A

200A

Rated service current

40-200A

225-400A

600-800A

40-200A

Poles

3

3

4

4

Standard

UL489B

UL489B

UL489B

UL489B-F

Product certification

UL489B

UL489B

UL489B UL489B-F - CCC

Rated service voltage

1000VDC

1000VDC

1000VDC

1500VDC

Rated insulation voltage

1150VDC

1150VDC

1150VDC

1500VDC

25 kA (UL489 B, τ =1ms) 10 kA (UL489 F, τ =3ms)

Short circuit interrupting rating

7.5 kA

5 kA

10 kA

Trip unit

TMD-TMA

TMF-TMA

TMA

TMF

VISIT PRODUCT PAGE

— SACE® Tmax® PV

Adaptability, versatility and complete freedom

Molded case switches up to 1500VDC

T4N-D/PV T5N-D/PV T6N-D/PV T7N-D/PV T4N-D/PV-E T7N-D/PV-E

Rated service current

200A

400A 600-800A

1000A

200A 1000-1200A

Poles

3

3

4

4

4

4

Standard

UL489B UL489B UL489B UL489B UL 489 B-F

UL489B

UL489B/F – CCC DC 22A/DC-PV2

Product certification Rated service voltage

UL489B CCC

UL489B CCC

UL489B UL489B

UL489B

1000VDC 1000VDC 1000VDC 1000VDC 1500VDC 1500VDC

Rated insulation voltage

1500VDC 1500VDC

1150VDC 1150VDC 1150VDC 1150VDC

Short circuit interrupting rating

3 kA

5 kA

10 kA

18 kA

3 kA

18 kA

VISIT PRODUCT PAGE

— SACE® Tmax® PV

Adaptability, versatility and complete freedom

Circuit breakers up to 800VAC

T4V-HA

T5V-HA

T5X-HA

Rated service current (A)

80-200 A

300 A

300 A

100% up to 150A 80% 200A

Rating

100%

100%

Poles

3 & 4

3 & 4

3 & 4

Standard

UL489 - IEC60947-2

UL489 - IEC60947-2

UL489

Rated service voltage

800 VAC

800 VAC

800 VAC

Rated insulation voltage Short circuit interrupt rating

1000 VAC

1000 VAC

1000 VAC

25 kA

25 kA

35 kA

TMA

TMA

TMA

Trip units

-

PR221

PR221

VISIT PRODUCT PAGE

SACE® FORMULA ™ Molded Case Circuit Breakers (MCCB)

F e b r u a r y 2

— SACE® FORMULA™ Molded Case Circuit Breakers (MCCB) Simplicity and quality in a single product

— SACE® FORMULA™ Molded Case Circuit Breakers (MCCB) Simplicity and quality in a single product

PRODUCT DESCRIPTION

The SACE® FORMULA ™ Molded Case Circuit Breakers (MCCB) brings simplicity and quality together in some of the smallest dimensions available. The UL offering consists of two frames, A1 and A2, which reach up to 100A and 250A respectively. Both frames are available in the fixed version with front terminals and can be installed directly on the back plate of cubicles. The protection trip unit has fixed thermal and magnetic threshold values to put the circuit-breaker into service more rapidly. A reduced number of product codes simplifies selection and makes your ordering easier.

— SACE® FORMULA™ Molded Case Circuit Breakers (MCCB) Simplicity and quality in a single product

FEATURES AND BENEFITS

Easy to order Quick and easy selections with 1, 2, 3 pole versions of the circuit breakers, makes ordering easy

Ready to use Fixed Long Time (Overload) and Instantaneous (Short Circuit) protection settings for the trip units, multiple polarities dedicated to various application, and accompanying range of accessories save time putting FORMULA into service

Compact and competitive Extremely compact dimensions and coordinated depths mean standardized dimensions and savings in distribution boards design

— SACE® FORMULA™ Molded Case Circuit Breakers (MCCB) Simplicity and quality in a single product

FORMULA A1

FORMULA A2

1-pole

2-pole

2-pole

3-pole

A1

A2

Frame Size (A)

100

250

Rated current, In (A)

15-100

125-250

Poles

1,2,3

2,3

Rated service voltage, (AC) 50-60 Hz (DC)

240 (1p,2p,3p) 125 (1p), 250 (2p,3p)

240 (2p,3p) 250(2p,3p)

A

N

A

N

Interrupt Rating (kA) 240V 50-60 Hz (AC)

1p 2p,3p

1p 2p,3p

2p,3p

2p,3p

10

10

18

25

10

25

Trip Unit

Thermal magnetic Fixed (TMF)

Thermal magnetic Fixed (TMF)

VISIT PRODUCT PAGE

DIN rail Miniature Circuit Breakers

F e b r u a r y 2

— DIN rail Miniature Circuit Breakers A giant legacy of electrical safety

— DIN rail Miniature Circuit Breakers A giant legacy of electrical safety

PRODUCT DESCRIPTION

The miniature circuit breaker (MCB) range helps ensure extreme performance and protection features up to 100 amps with interrupting rating of up to 50kA securing installations against higher hazardous faults. These MCBs are designed to maximize ease of use, and are built to deliver safety, reliability and quality.

— DIN rail Miniature Circuit Breakers A giant legacy of electrical safety

FEATURES AND BENEFITS

Performance • Compact dimensions and high performance with SUP200M and S800U MCBs • Current limiting MCBs Global platform • UL products rated for CSA and IEC,VDE,KC • Serviceability across the globe • 10,000 variants of MCB are manufactured globally

Connectivity • Full line of compatible accessories • LOTO with special safety feature • Specialized Ring tongue busbar for ring tongue MCBs

Ease of use & safety • With higher interrupting ratings ,minimal risk to hazardous faults • Finger safe terminals

— DIN rail Miniature Circuit Breakers A giant legacy of electrical safety UL 489 Branch breakers

Technical criteria Product Identity

SU200M SUP200M SU200MR

S200UDC SU200ML

S800U S804U-UCZ

30/50kA (1- /multipole)

Interrupt rating

10 kA

14 kA

10 kA

14 kA

14 kA

10kA

Current rating

0.2 to 63A 1 to 40A (K:35)

0.2 to 63A

1 to 63A

0.2 to 63A 10 to 100A

10 to 80A

480Y/277 V AC 48/96 V DC 480Y/277 V AC 480Y/277 V AC

Rated voltage

125/250 V DC

230 V AC

240 V AC

600 V DC

Characteristics

C,K,Z

C,K,Z

K

K,Z

C,K,Z

Z(B),K

Z(K)

Poles

1P - 4P

1P - 3P

1P - 4P

1P - 2P

1P - 4P

1P - 4P

4 in series

Max 1-pole dimension (in)

2.98x0.68x4.37 2.98x0.68x4.37 2.98x0.68x4.52 3.06x0.68x3.62 2.72x0.68x3.72 3.48x1.04x3.74 3.48x4.17x5.59

Auxiliary contact

yes

yes

yes

yes

yes

yes

yes

Bell alarm Shunt trip

yes

yes

yes

yes

yes

yes

Yes

yes

yes

yes

yes

yes

yes

yes

Upgraded to 125/250 VDC 60/125 VDC for 50 – 63 A

Smallest/comp act UL 489 MCB 230V range 14kA

Ring tongue terminal Compact for 30/50kA

14kA Interrupt Rating

Ring tongue terminal

Higher DC rating

Special features

VISIT PRODUCT PAGE

— DIN rail Miniature Circuit Breakers A giant legacy of electrical safety UL 1077 supplementary protectors

Technical criteria Product Identity

ST200M S200MR S200MUC

S800S

S800C

S300P

ST200MTR

S800P

ST200MTR :6kA ST200MTR(DC) :10kA

Interrupt rating

10/5 kA

10kA up to 10kA Up to 30kA Up to 20kA

10kA

Up to 20kA

Current rating

0.5 to 63A

0.2 to 63A

0.2 to 63A

0.5 to 63A

10 to 63A

0.2 to 63A

0.5 to 63A 80 to 100A

480Y / 277 V AC 1P: 250 V DC and 2+4P: up to 500 VDC

480Y/277 V AC 60/125 V DC (1-/2-pole)

480Y/277 V AC 250/500 V DC (1-/2-pole)

480Y/277 V AC 60/125 V DC (1-/2-pole)

480Y/277 V AC up to 500 V DC

480Y/277 V AC up to 500 V DC

Rated voltage

480Y/277 V AC

630Y/347 V AC

Characteristics

B,C,D,K,Z

K

C,K,Z

B,C,D,K

B,C,D,K B, C, D, K, Z

K and Z

B,C,D,K

1P- 4P AC 1P, 2P and 4P DC

Poles

1P - 4P

1P - 4P

1P - 4P

1P - 4P

1P - 4P

1P - 4P

1P - 4P

Max 1-pole dimension (in) Auxiliary contact

2.98x0.68x3.46 2.98x0.68x3.94 2.98x0.68x3.46 3.48x1.04x3.74 3.48x1.04x3.74 2.98x0.68x3.46 2.95x0.68x3.94 3.48x1.04x3.74

yes yes yes

yes yes yes

yes yes yes

yes yes yes

yes yes yes

yes yes yes

yes yes yes

yes yes yes

Bell alarm Shunt trip

Bottom-mount aux.Contact

yes

-

yes

-

-

yes

-

-

Ring tongue Busbar Ring tongue terminal

Busbars

yes

yes

yes

-

-

yes

-

Also in Ring tongue terminal

Also in Ring tongue terminal

TPI and DIN rail release without tool

Also in Ring tongue terminal

Ring tongue terminal

250/500 V DC (1-/2-pole)

Special features

-

VISIT PRODUCT PAGE

DIN rail Residual Current Devices

F e b r u a r y 2

— DIN rail Residual Current Devices Ultimate protection of equipment

— DIN rail Residual Current Devices Ultimate protection of equipment

PRODUCT DESCRIPTION

The residual current device (RCD) help protect equipment against ground faults. RCDs work together with Miniature Circuit Breakers (MCB) or fuses, covering the whole system against potentially damaging thermal and dynamic stresses of any overcurrent. DIN rail F200 series ground fault equipment protection (GFEPs) are available in multiple versions with 10, 30, 100, 300, and 500 mA ground-fault sensitivity.

— DIN rail Residual Current Devices Ultimate protection of equipment

FEATURES AND BENEFITS

Global platform • Global certification for the same part

Easier to install • Terminals equipped with fail safe feature to avoid improper installation. • Double slot for connection with cables and PS busbars

number covering all worldwide markets (UL,CSA,IEC and CCC)

Performance • Available in 10, 30, 100, 300, and 500 mA ground-fault sensitivity • UL DS201 RCBO has integrated MCB with GFEP which offers 33% space reduction; reduced wiring and labor cost

Integration • Compatible with System pro M Compact accessories • Test push button to verify operation

— DIN rail Residual Current Devices Ultimate protection of equipment

F200 A AP-R

F200 A 110V

F200 A 400Hz

F200 A 16 2/3 Hz

F200 AC F200 A

F200 A S

F200 B F200 F

IEC/EN 61008, IEC/EN 62423 2nd ed

IEC 61008 1; IEC 61008-2-1; UL 1053

IEC/EN 61008-1; IEC/EN 61008-2-1

IEC/EN 61008-1; IEC/EN 61008-2-1

IEC/EN 61008; IEC 62423

Standards

IEC/EN 61008-1; IEC/EN 61008-2-1; UL 1053 1

Type

AC

A A AP-R

A S

A

A

A

B

F

Poles

2P, 4P (for 125 A only 4P)

2P, 4P

4P

2P, 4P

2P, 4P

2P, 4P

25,40,63,8 0, 100,125 A

25,40,63,8 0, 100 A

16,25,40, 63, 80, 125 A

Rated current ln

16,25,40,63,80,100,125 A

40, 63, 80, 100, 125 A

25,40 A

63 A

25-40-63 A

Rated sensitivity l∆n

0,1-0,3-0, 5-1 A

0,03-0,3-0, 5 A

0,01-0,03-0,1-0,3-0,5 A 0,03 A

0,03 A 0,03 A

0,03-0,3 A 0,03 A

VISIT PRODUCT PAGE

— DIN rail Residual Current Devices Ultimate protection of equipment UL & CSA approved DS201 RCBO (UL 1053/1077)

PRODUCT DESCRIPTION DS201 UL is a combination of a 30 mA RCD and MCB with trip curves B, C and K. This Product replaces the DS951 UL product line.

DS201 UL (6kA) Char B 6-40 DS201 UL (6kA) Char C 6-40 DS201 UL (6kA) Char K 10-20

APPLICATION Protection of supplementary circuits against overload, short circuit and ground fault, wherever space is needed

RCBO

02

Other circuit protection

DIN rail Fuse Holder – E90

F e b r u a r y 2

— DIN rail Fuse Holders – E90 Uncompromising performance

— DIN rail Fuse Holders – E90 Uncompromising performance

PRODUCT DESCRIPTION

E90 fuse holders and fuse switch disconnectors provide protection against short-circuits and overloads. The fuse disconnector can be sealed or padlocked to ensure the operator’s safety during maintenance. Versions with blown-fuse indicators enable you to check whether the fuse is still working correctly or not.

— DIN rail Fuse Holders – E90 Uncompromising performance

FEATURES AND BENEFITS

Safe • To ensure protection and safety during maintenance and avoid any accidental switching, fuse holders can be sealed in closed position and padlocked in open position.

Space saving • The compact dimensions allow the switchboard door to close even when the fuse holder is open, ensuring total safety during maintenance

Easy to install • The fuse holder profile has been

Reliability • Venting grooves and cooling

designed for maximum ease of use: the 90 ° flip hinge with ergonomic knob, makes the replacement of fuses easier even in small spaces or when wearing protective gloves

chambers improve heat dissipation even in multiple-pole configurations • The reduced operating temperature inside fuse holders ensures durability and reliability of the devices over time

— DIN rail Fuse Holders – E90 Uncompromising performance

E90/CC (with rejection membrane)

E90/PV 1000V DC

E90/32 PV1500V

Technical Criteria

E90/Midget

E90/J

Rated current

32A

30A,60A

30A

30A

30A

Rated voltage

600V

600V

600V

1000V

1500V

Type of current

AC/DC

AC/DC

AC/DC

DC

DC

1P,1P+N,2P,3P, 3P+N,4P

1P, 1P+N, 2P, 3P, 3P+N and 4P

Poles

1P,2P,3P

1P,2P

1P

Max 1pole dimension (in)

2.52x0.71x3.35 2.9x1.38x4.41

2.52x0.71x3.35

2.52x0.71x3.35 2.52x0.89x5.28

10 × 85 mm & 10/14 × 85 mm fuses

10.3x38mm (AC-22B)

10.3x38mm (AC-22B)

Fuse type

Class J

Class CC

Can be sealed closed

Yes

Yes

Yes

Yes

Yes

Can be padlocked open

Yes

Yes

Yes

Yes

Yes

VISIT PRODUCT PAGE

03

Surge protective devices

ABB Surge Protective Devices

F e b r u a r y 2

— ABB Surge Protective Devices Be ready

— ABB SPDs Be ready

PRODUCT DESCRIPTION

Ensure your equipment is ready for the unexpected and mitigate against the constant wear and tear of low-level transient surges with ABB’s SPDs.

ABB’s portfolio offers a wide variety of SPDs, from UL Type 1 line side units to compact data line SPDs specifically designed for critical data feeds. SPDs are certified in accordance with UL 1449 5th Edition and come with a standard ABB warranty to bring you peace of mind.

— ABB SPDs UL type ratings

UL Type 1 SPD (line side)

UL Type 2 SPD (load side)

• Type 1 SPDs are permanently connected devices that can be installed anywhere between the secondary of the utility service transformer and the main distribution disconnect. • A Type 1 SPD can also be installed anywhere on the load side of the main distribution and can be installed without the need for external over-current protection (does not require an upstream fuse or breaker). • Type 3 SPDs are installed at a conductor length of 10 meters (30 ft) or more from the electrical panel the are protecting. • These devices are typically cord-connected, direct plug-in, receptacle-type SPDs installed at the load equipment being protected.

• Type 2 SPDs are permanently connected devices that must be installed on the load side of the main distribution disconnect. • Type 2 devices may or may not

require external over-current protection (i.e. upstream fuse or breaker).

UL Type 3 SPD (cord-connected)

UL Type 4 SPD

• Type 4 SPDs are considered component SPDs. • Type 4 SPDs are not intended to be used by themselves and must be integrated into other systems. • Type 4 SPDs, once installed inside another piece of equipment, can be tested as either Type 1 or Type 2 SPDs.

No ABB offering

— ABB SPDs OVRH portfolio

Name

OVRHTP

OVRHMSU

OVRHT3D

Connection ampacity

4000 and below

24 A

400 A and below

SPD type

Type 1 and Type 2

Type 4 for Type 2

Type 1

Certifications

UL 1449

UL 1449

UL 1449

60, 80, 100, 120, 160, 200, 240, 300, 400 kA per phase

Surge ratings

50 kA per phase

50 kA per phase

LEDs

Yes

Yes

Yes

Dry relay contacts

Standard

Not available

Not available

EMI filter

Optional

Not available

Surge counter

Optional

Not available

Not available

Warranty

10 years

5 years

3 years

— ABB SPDs DIN Rail SPD portfolio: OVRT family

Name

OVRT2

OVRT2 1N

OVRT2 2L

OVRT2 2N

OVRT2 3L

OVRT2 3N

Number of poles

1p units

1p+N+Gnd

2p+Gnd

2p+N+Gnd

3p+Gnd

3p+N+Gnd

Single-phase 2w+Gnd

Split-phase 2w+Gnd

Split-phase 3w+Gnd

Three-phase 3w+Gnd

Three-phase 4w+Gnd

Network type

All networks

SPD type

Type 4 for Type 2 Type 4 for Type 2 Type 4 for Type 2 Type 4 for Type 2 Type 4 for Type 2 Type 4 for Type 2

UL 1449 CSA C22.2 No. 269.4-14

UL 1449 CSA C22.2 No. 269.4-14

UL 1449 CSA C22.2 No. 269.4-14

UL 1449 CSA C22.2 No. 269.4-14

UL 1449 CSA C22.2 No. 269.4-14

UL 1449 CSA C22.2 No. 269.4-14

Certifications

Marking

cURus, CE

cURus, CE

cURus, CE

cURus, CE

cURus, CE

cURus, CE

15 kA 40 kA

15 kA 40 kA

15 kA 40 kA

15 kA 40 kA

15 kA 40 kA

15 kA 40 kA

Surge ratings

Up to 347/600 V AC

Voltage

Up to 600 V AC Up to 347 V AC 120/240 V AC 120/240 V AC Up to 480 V AC

End-of-life signal contact Replaceable cartridge

Only on 40 kA units

Only on 40 kA units

Only on 40 kA units

Only on 40 kA units

Only on 40 kA units

Only on 40 kA units

Yes

Yes

Yes

Yes

Yes

Yes

SPD technology

MOV

MOV

MOV

MOV

MOV

MOV

No (upstream protection needed)

No (upstream protection needed)

No (upstream protection needed)

No (upstream protection needed)

No (upstream protection needed)

No (upstream protection needed)

Thermally protected

— ABB SPDs DIN Rail SPD portfolio

OVR PV Type 2 series Specifically designed for photovoltaic DC installations, the OVR PV family provide a safe and reliable surge and lightning protection of solar panels and converters.

Available for 1000 and 1500 V DC applications.

OVR PV Type 2 series UL 497B listed SPDs specifically designed for RS 485 and Fieldbus applications, such as Profibus DP. Available as a compact 4-pair module or the Slim Line 1-pair version for installations where a high number of lines require protection.

— ABB SPDs Legacy portfolio: Wall-mount SPDs

TPME & TPHE Wall-mount SPDs with enhanced thermal protection • UL Listed 1449 5th Edition, Type 1, Type 2 • cUL Listed, CSA C22.2 • UL 96A, for use in lightning protection systems • TPME: Patented thermal fuse technology • TPHE: Thermally protected MOV design eliminates the need for additional upstream over-current protection • Standard features include a surge counter, audible alarm, indication lights, dry contacts and NEMA 4 painted steel enclosure • 10-year limited warranty

TPME & TPHE

TLE & TME Wall-mount SPDs • UL Listed 1449 5th Edition, Type 2 • cUL Listed, CSA C22.2 • Compact and economical design for use

at medium-exposure distribution or branch panels • TME: UL 96A, for use in lightning protection systems • TLE: Patented thermal fuse technology • Standard features include status indicating LEDs, form C dry contacts for remote monitoring and NEMA 12 painted steel enclosure • 10-year limited warranty

TLE

TME

— ABB SPDs Legacy portfolio: Integrated SPDs

TPME A: Designed to connect within ReliaGear ™ panelboards • UL Listed 1449 5 th Edition, Type 1,Type 2 • cUL Listed, CSA C22.2 • Factory installed in A Series ™ panels • Connects directly to the A Series panelboard bus bars • Standard features include a surge counter, audible alarm, indicating lights, dry contacts and NEMA 4 painted steel enclosure • 10-year limited warranty TPME: Designed for ABB distribution equipment • UL Listed 1449 5 th Edition, Type 1,Type 2 • cUL Listed, CSA C22.2 • Connect to the panelboard or switchboard bus bars • Thermally protected MOV design eliminates the need for additional upstream over-current protection • Standard features include a surge counter, audible alarm, indicating lights, dry contacts and NEMA 4 painted steel enclosure • 10-year limited warranty TPHE: Designed for ABB distribution equipment • UL Listed 1449 5 th Edition, Type 2 • cUL Listed, CSA C22.2 • Connect to the panelboard or switchboard bus bars • Thermally protected MOV design eliminates the need for additional upstream over-current protection • Standard features include a surge counter, audible alarm, indicating lights, dry contacts and integral surge-rated disconnect • 10-year limited warranty

TPME A

TPME

TPHE

— ABB SPDs Legacy portfolio: Box Extensions

TPME & TPHE 9” Extensions: Designed for ABB distribution equipment • UL Listed 1449 5th Edition, Type 2 • cUL Listed, CSA C22.2 • The 9” box extension SPD is field installed and attaches neatly to the top or bottom of a standard panel • The true maximum surge current rating, unlimited by fusing, has been proven in successful third-party tests • Standard features include a surge counter, audible alarm, indicating lights and dry contacts • 10-year limited warranty TPHE: Designed for ABB distribution equipment • UL Listed 1449 5 th Edition, Type 2 • cUL Listed, CSA C22.2 • Connect to the panelboard or switchboard bus bars • Thermally protected MOV design eliminates the need for additional upstream over-current protection • Standard features include a surge counter, audible alarm, indicating lights, dry contacts and integral surge-rated disconnect • 10-year limited warranty

TPME & TPHE 9” Extensions

TPME & TPHE 24” Extensions

VISIT CATALOG

04

Power Distribution Systems

SMISSLINE TP®

F e b r u a r y 2

— SMISSLINE

Touch-safe, pluggable UL508 Interiors More safe, flexible, and efficient energy distribution

— SMISSLINE More safe, flexible, and efficient energy distribution

PRODUCT DESCRIPTION

SMISSLINE is a modular, IP 20 rated plug-in distribution system designed to enhance safety, flexibility, and efficiency in energy distribution. The system supports easy expansion and modifications, making it ideal for dynamic environments like data centers and hospitals. Its plug-in technology and vertical installation streamline maintenance and save space, making it a practical solution for critical power applications.

— SMISSLINE Touch-safe, pluggable UL508 Interiors

WHAT’S SO SPECIAL ABOUT SMISSLINE?

Safety: Smissline is a plug-in socket system with a unique integrated bus bar design, allowing the assembly to remain fully touch-proof (IP20) even when plugging in and unplugging devices. Flexibility: The socket design and coordinated device portfolio offers unparalleled flexibility during installation, maintenance, and any necessary adaptations, allowing users to quickly move components, adjust plug-in contacts for convenient phase balancing, create electrically independent sockets on the same system, or expand the system with additional sections. Efficiency: Smissline’s compact footprint can also help reduce your footprint by up to 30% compared to traditional din rail installation when used in the vertical configuration.

— SMISSLINE Touch-safe, pluggable UL508 Interiors

• UL 508 Interior • 125 and 250A systems version available • Incoming: Feeder terminals and direct feed XT4 options • Max Rated Voltage (busbar) • UL508: 600 V AC • Series rating with Tmax® XT4 • 50 kA at 480Y/277V • Directly pluggable MCBs up to 40A, 100% rated (SUP400M family, K and C tripping curves available) • Direct plug-on branch breakers, plug-in adaptors available for additional components up to 63A and motor starting solutions up to 32A. • Padlock LOTO devices available for branch MCBs

— SMISSLINE Busbar system 125 A

A variety of 125 A starter packs are available and include the sockets, L and R end pieces, and busbars cut to the specified length.

— SMISSLINE Power bar system 250 A

A variety of 250 A starter packs are available for the standard power bar and direct feed systems and include the sockets, L and R end pieces, and busbars cut to the specified length.

— SMISSLINE - Power bar system 250 A Direct feed busbar system to Tmax® XT4

The direct-feed starter pack solutions allow for simple direct connection from the power bar system to the SACE® Tmax® XT4 MCCB.

Direct-feed systems are built for vertical configuration with one or two busbar systems in a single enclosure.

SMISSLINE TP system for UL 508 Industrial Control Equipment, CSA C22.2 No.14 Industrial Control Equipment UL File E222110

Control Equipment UL File E222110

UL rated voltage

600 V AC

UL rated current (end feed)

250 A

UL short circuit rating

50 kA (480 V), 35 kA (600 V) with Tmax® XT4 250A

VISIT CATALOG

05

Automatic transfer switches

TruONE®

F e b r u a r y 2

— TruONE® All-in-one automatic transfer switch

— TruONE® All-in-one automatic transfer switch

PRODUCT DESCRIPTION

The all-new TruONE® is the world’s first true purpose-built automatic transfer switch, engineered to incorporate switch and controller in one seamless unit. Performance tested beyond standard requirements, TruONE® stands ready to ensure the steady delivery of critical power at all times. Its self-contained design reduces the number of wires and connections, which speeds installation and minimizes the potential for connection failures to ensure best-in-class reliability. Its predictive maintenance and modular components reduce downtime and service costs. And its advanced connectivity is ready for the future.

— TruONE® All-in-one automatic transfer switch

FEATURES AND BENEFITS

Easy to install • 1 connection not 20

Simplified service • Quick Swap HMI • Mechanism replacement in as little as 10 minutes • Over 95% fewer spare parts High performance • Embedded current sensing • High time-based withstand and closing ratings (WCR) available • Faster switching <50ms in every frame

• 200-480VAC True voltage agnostic • All accessories snap on, even within a finished panel.

Proactive outage prevention • High current protection and alarm • Contact wear & prediction • 5 embedded temperature sensors • Available 24/7 monitoring

— TruONE® All-in-one automatic transfer switch

HIGHLIGHTS

• The all-new ATS from ABB is the world’s first true, purpose-built ATS integrating switch and controller in one seamless unit • With UL short-time ratings (STR) in every frame, TruONE stands ready to ensure the steady delivery of critical power at all times • Its predictive maintenance (Level 4 controller) and modular construction simplify service • And its advanced connectivity is ready for the future • Fast in-phase open transition, up to 50ms transfer time; delayed available too

RANGE

UL 30-200A / IEC 200-250A

UL 260A / IEC 315-400A

UL 400-600A / IEC 500-800A

UL 800-1200A / IEC 1000-1600A

— TruONE® All-in-one automatic transfer switch

CONTROLLER TYPES

Level 2 controls

Level 3 controls

Level 4 controls

Standard • Standard features to meet the standard application reqs. • DIP switch controls • Mains-Mains and Mains-Gen applications • Specific breaker ratings

Advanced • Enhanced product features • LCD screen controls • Programmable I/O, and field mount comm. & I/O • Flexible time delays • Specific breaker ratings

Pro • Superior product features • Touch screen controls • Power measurement • Predictive maintenance • UL Short-time, time-based, and specific breaker ratings

VISIT PRODUCT PAGE

06

Disconnect switches

OS Disconnect Switches – Fusible

F e b r u a r y 2

— OS Disconnect Switches – Fusible World class performance in the most demanding applications

— OS Disconnect Switches – Fusible World class performance in the most demanding applications

PRODUCT DESCRIPTION

OS switch fuses are ideal for demanding applications where continuity of operations is vital even in case of a fault. These devices are used for protection in a wide range of applications. They are often found in power distribution boards and control cabinet in heavy industrial use. They are built to meet installation requirements close to the main transformer.

— OS Disconnect Switches – Fusible World class performance in the most demanding applications

FEATURES AND BENEFITS

Space saving • Modular and flexible construction, which can include adjustable periscopic shaft, allows for different arrangements of the poles and handle, providing unique space saving solutions Reliable in extreme conditions • Change-over disconnect switches by ABB are extremely well suited for industrial applications • Equipped with CTI (comparative tracking index) of over 600 V, making OT_C great for use in tropical environments

Energy efficiency • Our disconnects come with a real one pole construction in even higher ratings (one line per power line), creating savings in terms of energy consumption by reducing power loss • A single terminal per pole across the entire range also eliminates the need to use additional fixing sets to do connections

— OS Disconnect Switches – Fusible World class performance in the most demanding applications

OS200

OS Mini

OS Gamma OS Gamma

OS400

OS600

OS1200

OS800

Standard

UL98 UL98 UL98 UL98 UL98 UL98 UL98

UL98 1200

I [A]

30

60

100

200 600

400 600

600 600

800 600

VAC [V] VDC [V]

600

600

600

600

250

250

250

250

250

250

250

250

Fuse type

CC, J

J

J

J

J

J

L

L

Handles, shafts, etc. must be ordered separately

VISIT PRODUCT PAGE

OT Disconnect Switches – Non-Fusible

F e b r u a r y 2

— OT Disconnect Switches – Non-Fusible High performance, compact solution

— OT Disconnect Switches – Non-Fusible High performance, compact solution

PRODUCT DESCRIPTION

Manual switch-disconnectors by ABB are suitable for a wide range of demanding applications ranging from machinery to entire photovoltaic installations. They have been designed to be compact and reliable, offering high performance in even the most demanding environments.

— OT Disconnect Switches – Non-Fusible High performance, compact solution

FEATURES AND BENEFITS

Space saving • Designed for easy and cost-efficient installation, maintenance and use. • Modular design and smaller dimensions enable 2-, 3- and 4-pole installation with different position of the switching mechanism to suit needs and spatial requirements • Devices can be optimized in relation to busbar and cable connections as well as handles and other accessories lifespan and offer reliable performance • Durability ensured by testing switches against the IEC609473, UL508, UL98 and CSA standards Reliable in extreme conditions • Designed, built and tested for the best possible performance • Designed to be virtually maintenance free across their entire extended

Easy to install • The adjustable shaft (for external handles) and mounting feet, along with snap-on auxiliary contacts and terminal shrouds create considerable savings in terms of installation time and costs • The shaft can be adjusted to various installation depths, eliminating the need for special cutting tools • Flexible installation orientation means the switches work just as well installed horizontally or vertically

— OT Disconnect Switches – Non-Fusible High performance, compact solution

OT16, 25,40F_

OT63, 80F_ OT30, 60, 100F_

OT160G

Standard

UL508

UL508 60 - 80

UL98

UL98

I [A]

20 - 30 - 40

30 –60 - 100 100 (125 recognized)

VAC [V] VDC [V]

600

600

600

600

250

250

Handles, shafts, etc. must be ordered separately

VISIT PRODUCT PAGE

— OT Disconnect Switches – Non-Fusible High performance, compact solution

OT200U_

OT400U_

OT600U_

OT800U_ OT120U_

OT1600U_ OT200U_

Standard

UL98

UL98

UL98

UL98

UL98

I [A]

200

400 600

600 600

800/1200

1600/2000

VAC [V] VDC [V]

600

600

600

250

250

250

250

250

Handles, shafts, etc. must be ordered separately

VISIT PRODUCT PAGE

OT Plus Disconnect Switches – Non-Fusible

F e b r u a r y 2

— OT Plus Disconnect Switches – Non-Fusible One giant leap to progress

— OT Plus Disconnect Switches – Non-Fusible One giant leap to progress

PRODUCT DESCRIPTION

The all-in-one OT Plus Switch-disconnector range offers supreme protection and cutting-edge innovation for distribution and sub-distribution applications from 16A* up to 100A, with 3-, 4-, 6-, and 8-pole options. Whether your chosen application is low demand or requires the highest levels of continuity and safety, you have more options than ever before

*30A-100A available now, smaller sizes to be released later in 2025

— OT Plus Disconnect Switches – Non-Fusible One giant leap to progress

FEATURES AND BENEFITS

Adaptable Support more applications thanks to adjustable fourth-pole timing, which allows two different time offsets within the same switch: simultaneous or early make / late[1]break. Find the right fit and install faster with overlapping current ratings, quick-spring terminals and more mounting positions. Reliable Improve safety for people and assets, thanks to our true fourth-pole design, which reduces the risk of faults. Simplify and strengthen security with easier ways to lock and access the operating handle.

Sustainable Go greener with a range that cuts power losses by up 27%, that is designed for a circular economy and made with high portion of recycled materials. Additionally, the OT Plus switch is over 95% recyclable.

— OT Plus Disconnect Switches – Non-Fusible One giant leap to progress

OT63G2-, OT80G2-

OT30G3-, OT60G3-, OT100G3

Standard

UL60947-4-1

UL98

I [A]

63, 80

30, 60, 100

VAC [V]

600

600

*The G1 frame will be released later in 2025 **The current OT switch offer (20A to 100A) will transition to OT Plus

VISIT CATALOG

OTDC Disconnect Switches – DC Switches

F e b r u a r y 2

— OTDC Disconnect Switches – DC Switches Switches for all DC applications

— OTDC Disconnect Switches – DC Switches Switches for all DC applications

PRODUCT DESCRIPTION

The OTDC disconnects for photovoltaic and ESS applications range from 16A to 1000A, UL, and 16A to 1600A, IEC. Specially designed for DC applications which offer reliable switching for a wide range of photovoltaic (PV) applications and Energy Storage Systems (ESS) applications up to 1500VDC. DC disconnects are optimized for photovoltaic (PV) and Energy Storage Systems (ESS) applications. In PV applications, the DC disconnects are used inside string combiners and inverters. In ESS applications, the disconnects are used as the main switch of energy storage Power Conversion Systems (PCS) and/or in the battery section to protect battery racks.

— OTDC Disconnect Switches – DC Switches Switches for all DC applications

FEATURES AND BENEFITS

High performance • The unique 2-pole switch design has been optimized to break mid-currents up to 2000V DC easily and reliably, across the complete lifespan of the installation • OTDC switch-disconnectors have been certified according to all main international standards and can be used in demanding conditions

Efficient design • OTDC switch-disconnectors have been designed with sustainability in mind when it comes to operation, transportation, and installation • OTDC has a compact design, high energy efficiency and fast installation • Bulk package options decrease waste without compromising the quality of the product during transportation

Speed up your projects • Time is money

• With OTDC switch-disconnectors, you have the flexibility to design the best installation and equipment, while decreasing labor time

— OTDC Disconnect Switches – DC Switches Switches for all DC applications

OTDC XS-Series

OTDC S-Series

OTDC M-Series

Standard

UL508i

UL98B

UL98B

I [A]

16/25/32

100/200/250 250/320/400/600/800/1000

VDC [V]

600

1500

1000/1500

Handles, shafts, etc. must be ordered separately

VISIT PRODUCT PAGE

OT_C Disconnect Switches – Manual change over switches

F e b r u a r y 2

— OT_C Disconnect Switches – Manual change-over switches Securing your power to perform

— OT_C Disconnect Switches – Manual change-over switches Securing your power to perform

PRODUCT DESCRIPTION

OT_C change-over disconnects for a smooth and safe transition from one power source to another. In case of power source failure, whether planned or unplanned, a rapid switch to back-up power is often crucial. Open transition manual change-over switches designed according to UL/CSA certification from 30 to 800 Amperes (UL).

— OT_C Disconnect Switches – Manual change-over switches Securing your power to perform

FEATURES AND BENEFITS

Space saving • Modular and flexible construction, which can include adjustable periscopic shaft, allows for different arrangements of the poles and handle, providing unique space saving solutions Reliable in extreme conditions • Change-over disconnect switches by ABB are extremely well suited for industrial applications • Equipped with CTI (comparative tracking index) of over 600 V, making OT_C great for use in tropical environments

Energy efficiency • Our disconnects come with a real one pole construction in even higher ratings (one line per power line), creating savings in terms of energy consumption by reducing power loss • A single terminal per pole across the entire range also eliminates the need to use additional fixing sets to do connections

— OT_C Disconnect Switches – Manual change-over switches Securing your power to perform

OT16, 25, 40_C

OT63, 80_C

OT30, 60, 100_C

Standard

UL508

UL508 60 - 80

UL98

I [A]

16 - 25 - 40

30 - 100

VAC [V]

600

600

600

Handles, shafts, etc. must be ordered separately

VISIT PRODUCT PAGE

— OT_C Disconnect Switches – Manual change-over switches Securing your power to perform

OT200U_C

OT400U_C

OT600U_C

OT800_C

Standard

UL98

UL98

UL98

UL98

I [A]

200 600

400 600

600 600

800 600

VDC [V]

Handles, shafts, etc. must be ordered separately

VISIT PRODUCT PAGE

07

IEC-style contactors, overload relays and manual motor starter

Novolink ™

F e b r u a r y 2

— Novolink™ Advanced digitalization, simplified

— Novolink Advanced digitalization, simplified

PRODUCT DESCRIPTION

The all-new ABB Novolink ™ devices help digitalize motor starting solutions and gain insights into the connected loads. They're easy to design into existing wiring plans and connect to standard AF contactors. Installation is fast and simple, thanks to reduced wiring and fewer components, so engineering efforts are minimized. The Novolink devices enables predictive maintenance to reduce downtime, as well as increasing efficiencies and boosting cost savings. It‘s fully integrated into the B&R automation system. And the possibilities open up even more as full remote access to your data creates new maintenance service and revenue opportunities.

— Novolink Advanced digitalization, simplified

FEATURES AND BENEFITS

Innovation through digitalization • Enhanced analytics for improved performance – optimize the performance of your machine real-time with data driven decision making. The digitalized approach means that data can also be analyzed to find long term trends to improve performance • Cloud based predictive maintenance to pinpoint potential faults with speed, and keep system running at a high efficiency

Ease of design and commissioning • Novolink reduces number of

components and simplifies wiring directly pairing into the AF contactor • Transform your existing portfolio with Novolink to add a digital solution that pairs natively into the AF platform • Reduce engineering efforts – Novolink is designed to streamline high grade motor monitoring and protection, the standard controls are ready to use without additional engineering and there is not need for expensive special cabling or additional training.

— Novolink Advanced digitalization, simplified

— Novolink Advanced digitalization, simplified

PRODUCT FAMILY

SFM1

• Integrated current transformers up to 40A nominal current • Thermal motor model for motor protection (5E-30E) • Time to trip, time to cool, and actual thermal load level • THD, frequency, earth fault are also provided SC10

• Integrated voltage measurement up to 690VAC • Load monitoring (based on current, cos-phi and real power) • Record Energy consumption • High-end motor protection (TTT, TTC, status of thermal model, adj trip classes) • Startup current/time SCV10

• Remote control and monitoring via X2X directly from B&R PLC • Counters like motor operating hours, switching cycles, trip counters and more • Allows monitoring of short circuit protection devises using a digital input

VISIT PRODUCT PAGE

F e b r u a r y 2

Made with FlippingBook. PDF to flipbook with ease