NEMA FULL VOLTAGE POWER DEVICES, CONTROL SECTION 1
1-113
— Plug and play enclosed starters 3-phase starters, combination fusible disconnect switch 1
— HP rated, combination starters, fusible disconnect, non-reversing
Maximum motor HP ratings
Type 1
Type 4/12
Type 4X
Contactor size
200/ 208 V
220/ 240 V
460/ 480 V
575/ 600 V
Ordering code
Ordering code
Ordering code
Motor switching current 2
9
AF09 AF16 AF30 AF52 AF80
2 5
2 5
5
7.5 15 25 50 75
PS-AFSF13 PS-AFSF43 PS-0FSF13 PS-0FSF43
PS-AFSFX3 PS-0FSFX3 PS-1FSFX3 PS-2FSFX3 PS-3FSFX3 PS-4FSFX3
17 27 52 77
10 20 40 60
10 15 25 40
10 20 30 50
PS-1FSF13
PS-1FSF43
PS-2FSF13 PS-2FSF43
PS-3FSF13
PS-3FSF43
125
AF140
100
125
PS-4FSF13 PS-4FSF43
— HP rated, combination starters, fusible disconnect, reversing
Maximum motor HP ratings
Type 1
Type 4/12
Type 4X
Contactor size
200/ 208 V
220/ 240 V
460/ 480 V
575/ 600 V
Ordering code
Ordering code
Ordering code
Motor switching current 2
HP rated
9
AF09 AF16 AF30 AF52 AF80
2 5
2 5
5
7.5 15 25 50 75
PS-AFRF13 PS-AFRF43 PS-0FRF13 PS-0FRF43
PS-AFRFX3 PS-0FRFX3 PS-1FRFX3 PS-2FRFX3 PS-3FRFX3 PS-4FRFX3
17 27 52 77
10 20 40 60
10 15 25 40
10 20 30 50
PS-1FRF13
PS-1FRF43
PS-2FRF13 PS-2FRF43 PS-3FRF13 PS-3FRF43 PS-4FRF13 PS-4FRF43
125
AF140
100
125
— NEMA, combination starters, fusible disconnect, non-reversing 2
Maximum motor HP ratings
Type 1
Type 4/12
Type 4X
NEMA size
Contactor size
Continuous current
Ordering code
Ordering code
Ordering code
200 V 230 V 460/575 V
00
AF09 AF12 AF26 AF40 AF80
9
1.5
1.5
2 5
PSN-AFSF13 PSN-0FSF13 PSN-1FS*13 PSN-2FS*13 PSN-3FS*13 PSN-4FSF13
PSN-AFSF43 PSN-0FSF43 PSN-1FS*43 PSN-2FS*43 PSN-3FS*43 PSN-4FSF43
PSN-AFSFX3 PSN-0FSFX3 PSN-1FS*X3 PSN-2FS*X3 PSN-3FS*X3 PSN-4FSFX3
0 1 2 3 4
18 27 45 90
3
3
7.5 10 25 40
7.5 15 30 50
10 25 50
AF140
135
100
*Replace the asterisk with the code for the desired fusible disconnect switch option from the table.
— NEMA, combination starters, fusible disconnect, reversing 2
NEMA
Maximum motor HP ratings
Type 1
Type 4/12
Type 4X
NEMA size
Contactor size
Continuous current
Ordering code
Ordering code
Ordering code
200 V 230 V 460/575 V
Desired fusible disconnect switch option F For IEC — single and 3-phase
00
AF09 AF12 AF26 AF40 AF80
9
1.5
1.5
2 5
PSN-AFRF13 PSN-0FRF13 PSN-1FR*13 PSN-2FR*13 PSN-3FR*13 PSN-4FRF13
PSN-AFRF43 PSN-0FRF43 PSN-1FR*43 PSN-2FR*43 PSN-3FR*43 PSN-4FRF43
PSN-AFRFX3 PSN-0FRFX3 PSN-1FR*X3 PSN-2FR*X3 PSN-3FR*X3 PSN-4FRFX3
0 1 2 3 4
18 27 45 90
3
3
7.5 10 25 40
7.5 15 30 50
10 25 50
For NEMA 3-phase (208 and 240 V), no single phase Only for NEMA 3-phase (480 and 600 V), NEMA sizes 1, 2 and 3
L
AF140
135
100
*Replace the asterisk with the code for the desired fusible disconnect switch option from the table.
Coil voltage selection All AC-operated ordering codes include a 100–250 V AC coil. To select other coil voltages, substitute the code from the coil voltage selection chart for the last digit in the ordering code. Ex. : A 24–60 V AC coil is required for an AF09 contactor; use PS-AFSF11.
Volts
Hz
24-60
48-130
100-250
250-500
50/60
1
2
3
4
¹Overload relays, pilot device kits and control transformers must be ordered separately (see pages 115–122). ²Use code “L” for NEMA-rated combination starters (NEMA sizes 1, 2 and 3) being used at 480 or 600 V AC. ³Ratings listed are at 600 V AC.
Made with FlippingBook - Share PDF online