BuyLog Flippingbook OCT 2025

LOAD CENTERS, METER COMBOS, SINGLE SOCKET METERING, RESIDENTIAL CIRCUIT BREAKERS, AND SMART PANEL, BUYLOG SECTION 1

1-28

— ReliaHome meter combos

Dual main circuit breaker, ring, side by side socket layout, Class 320

Max branch circuit breaker circuits

Max branch circuit breaker spaces

Main wire size (AWG/ kcmil) Cu-Al (1) 800 or (2) 400 compression type (1) 800 or (2) 400 compression type (1) 1000 or (2) 350 pressure type (1) 800 or (2) 400 compression type (1) 800 or (2) 400 compression type (1) 1000 or (2) 350 pressure type (1) 800 or (2) 400 compression type

Main ampere rating

Front type

Bypass type Lever bypass

Factory installed service disconnect A2N200CTL-4SB

Secondary service disconnect

Ordering code TSD032UFCU

320

0

0

Semiflush

THHQL21125

24

48

Semiflush

None

A2N200CTL-2SB

THHQL21125

TM2432RMS 1,2

24

48

Surface

Link

THQMV200CTL

THHQL21125

TSDA2432UC42

400

24

48

Semiflush

None

A2N200CTL-2SB

A2A125CTL-4SB A2A150CTL-4SB A2A175CTL-4SB A2A200CTl -4SB A2N125CTL-4SB A2N150CTL-4SB A2N175CTL-4SB A2N200CTl-4SB THQMV200CTL

TM2440RMS 1,2

24

48

Semiflush

Link

THQMV200CTL

TSDA2440UC42

NOTE: All dual mains are 22kAIC. NOTE: All dual mains have underground UL incoming. NOTE: TGL2 (2) equipment ground kits ordered separately. NOTE: Please review your local utility specs to determine the SKU to fit your local needs. NOTE: The combined amperage of the two mains cannot exceed the main amperage rating of the SKU. IE: If your main is 300A then you cannot utilize a 200A and a 150A main because this has a combined amperage of 350.

1 For semi-flush applications, order surface enclosure load center and field installed kit, Ordering code SF400. 2 Stud provisions only provided.

NOTE: Circuit breakers must be ordered separately. Click here.

Made with FlippingBook - Online catalogs