LOW VOLTAGE POWER & INSULATED CASE CIRCUIT BREAKERS, BUYLOG SECTION 8
8-182
— Power Break II circuit breakers Draw-out breakers and accessories All devices UL Listed for factory or field installation except where noted.
Shutter Kit This field installable kit provides shutters used to prevent unintentional contact with potentially live primary disconnect stabs when a breaker is racked out of an energized switchboard compartment.
Racking Tool The racking tool is a drive wrench with a square 1/2" socket that engages the racking mechanism of the draw-out breaker.
Frame Rating
Product Number
All
TDORT
Frame Rating
Product Number
800-2000A
SPDSS20 SPDSS30 SPDSS40
Mechanical Interlocks Mechanical interlocks provide the same function as the walking beam accessory for stationary breakers, except they are used with two draw-out breakers: mounted on common compartment centerline, in either the same vertical section or adjacent vertical sections.
3000A 4000A
By-Pass Switch Provides positive indication that the draw-out breaker or switch primary contact fingers are fully connected to the main bus in the substructure. Switch contacts change states only after the primary fingers are fully connected when the breaker is being moved from the DISCONNECTED position through the TEST position and into the CONNECTED position. May be used to provide control circuit continuity or downstream signaling that the draw-out breaker is connected in addition to the visual position indicator on the draw-out substructure. The By-pass switch accessory does not indicate either the TEST or DISCONNECTED position. The switch assembly mounts on the stationary frame and the actuator mounts to the carriage. Switch contacts are rated at 10A at 600 Vac, 0.75A at 125 Vdc, and 0.25A at 250 Vdc.
Envelope Size
Product Number
800-2000 2500-4000
SPDOWB20 SPDOWB40
Rail Kit This field installable rail kit may be used to shorten the two standard OEM substructure rails by 3-1/2 inches.
Product Number SPRAILS
Position Switch Provides positive indication when the draw-out breaker or switch primary contact fingers have been fully withdrawn from the main bus connections. Switch contacts change state only after the primary fingers are fully disconnected when the breaker is being moved from the CONNECTED position through the TEST position and into the DISCONNECTED position. May be used as part of a safety interlocking system in addition to the visual indicator on the draw-out substructure. The Position Switch accessory does not indicate either the TEST or CONNECTED position. The switch assembly mounts on the stationary frame and the actuator mounts to the carriage. Switch contacts are rated at 10A at 600 Vac, 0.75A at 125 Vdc, and 0.25A at 250 Vdc.
Number of Switch Elements
Product Number
2 NO/2 NC 4 NO/4 NC 6 NO/6 NC
TDOBP2L TDOBP4L TDOBP6L
Racking Padlock Provision The racking padlock provides a means for the user to prevent racking tool engagement, thereby preventing movement of the breaker between the DISCONNECTED, TEST and CONNECTED positions.
Frame Rating
Product Number
All
TDOPC
Number of Switch Elements
Lifting Bar The lifting bar provides a means of safely lifting a draw-out circuit breaker. A chain hook can be attached to the central hole in the lifting bar or a 1" diameter black iron pipe can be put through the two holes above the hooks, allowing two people to carry the breaker below waist level from either side of the breaker.
Product Number
2 NO/2 NC 4 NO/4 NC 6 NO/6 NC
SDOPS2L SDOPS4L SDOPS6L
Frame Rating
Product Number
All
TDOLB