BuyLog Flippingbook NOV 2024

LOW VOLTAGE POWER & INSULATED CASE CIRCUIT BREAKERS, BUYLOG SECTION 8

8-180

— Power Break II circuit breakers Neutral current sensors and POWER LEADER accessories

Neutral Current Sensors 1

Circuit Breaker Sensor Rating (Amperes)

Neutral Sensor Rating or Tap Settings (Amperes)

Breaker Frame (Amperes)

Product Number

200 400 400 800

200

TSVG302 TSVG304A TSVG306A TSVG308A TSVG808A TSVG810A TSVG812A TSVG816A TSVG820A TSVG808A TSVG810A TSVG812A TSVG816A TSVG820A TSVG825A TSVG830A

800

400/200 600/300 2 800/400 800/400 2 1000/500 1200/600 2 1600/1000 2000/1000 800/400 2 1000/500 1200/600 2 1600/1000 2 2000/1200 2500/1800 3000/2400 4000/3000

800-1600

Neutral Current Sensor

SSVG Neutral Current Sensors

1000 1000 1600 1600 2000 1000 1000 1000 1000 2000 2500 3000 4000

1600

For microEntelliGuard ™ trip units, the battery pack connects to the trip unit through the 15-pin connector. A battery pack adapter cable is required. For MicroVersaTrip ™ Plus and MicroVersaTrip ™ PM trip units, the battery pack connects to the trip unit through the rating plug test jack. The battery pack requires three standard 9 Vdc alkaline batteries (not included).

2000

3000

Description

Product Number

4000 TSVG940A 1 Match neutral current sensor rating (or tap setting) to circuit breaker sensor rating. 2 For use with multiple source ground fault protection schemes. Rating does not match EntelliGuard ™ TU and MicroVersaTrip ™ Plus or PM frame sensor. Neutral Current Sensors 1

Portable Battery Pack

TVPBP

EntelliGuard ™ TU, microEntelliGuard ™ Battery Pack Adapter Cable

TVPBPACC

POWER LEADER ™ Power Supplies Power supply for furnishing 24Vdc control power for EntelliGuard ™ TU, MicroVersaTrip ™ Plus and PM trip units.

Neutral Sensor Rating or Tap Settings (Amperes)

Product Number of Window Sensor

Breaker Frame (Amperes)

Circuit Breaker Sensor Rating (Amperes)

Inside Diameter (inches)

800

800

800/400

SSVG808W 4.25

Description

System Requirements

Product Number

2000/1200 SSVG820W 5.63 1600/1000 SSVG816W 5.63 1600/1000 SSVG816W 5.63

1200 3 1600 3 1600 2000 2500 3000 4000

1.5 ampere power supply Price one PLPS4G01 for each line-up. 45 trip units 4 and 100 ft. maximum.

1200

Input power, 100VA (85-265Vac or 100-370Vdc)

PLPS4G01

1600 2000 2500 3000 4000

2000/1200 3

SSVG820W 5.63

2500/1800 SSVG825W 5.63 4000/3000 SSVG940W 6.50

4 20 trip units maximum for EntelliGuard ™ TU

4000/3000 SSVG940W 6.50 1 Match neutral current sensor rating (or tap setting) to circuit breaker sensor rating. 3 At time of initial product release, the 1200A new HPC Switch was using 1600A installed sensors and a 1200A rating plug. Later models may or may not use 1200A phase sensors. Match Neutral sensor tap to HPC sensor rating. 3 Outline Drawing 10112973P1. Portable Test Set The portable, battery-powered test kit provides self-tests and functional trip/no trip tests. It also provides defeat of the ground fault function and can be used in conjunction with high current test equipment. Interface is via a plug on the front of the trip unit and test can be conducted with the breaker in service. Test kits use either 120 Vac power source or internal batteries (not included).

Reference Instructions

GEH-6492

POWER LEADER ™ Voltage Conditioner Conditions and scales 120 Vac to 1.76 Vac for use by the trip unit for voltage sensing. Provides transient protection. Voltage conditioners require isolation PTs.

Description

System Requirements

Product Number

Supplies isolated bus voltage signal to EntelliGuard ™ TU and MicroVersaTrip ™ PM trip units.

One set of 3 voltage conditioners required for each voltage sensing location. PTs also required.

PLVC1G01

Description

Trip Unit Type

Product Number

MicroVersaTrip only

TVRMS2

Reference Instructions

Portable Test Set

EntelliGuard ™ TU, microEntelliGuard ™ only

GTUTK20

GEH-5946

Portable Battery Pack The hand-held Portable Battery Pack provides an independent power source for EntelliGuard ™ TU, microEntelliGuard ™ , MicroVersaTrip ™ Plus and MicroVersaTrip ™ PM trip units as an alternative to a test set. The battery pack is used to power up the trip unit to set or adjust trip set points when the breaker is on the bench or otherwise not powered up.

Rating Plug Removal Tool Product Number TRTOOL

Made with FlippingBook - Online Brochure Maker