LOW VOLTAGE POWER & INSULATED CASE CIRCUIT BREAKERS, BUYLOG SECTION 8
— EntelliGuard ™ G circuit breaker EntelliGuard ™ G circuit breaker nomenclature
Digit 16 and 17 Over Current Protection Package Type
Over Current (OC) Protection Ground Fault LSI (S, switchable) (I, switchable ANSI only) LSIG (S, switchable) (I, switchable ANSI only)
Code
L3 L4 L5 L6 L7 L8 L9 LC LD LE LF LG LH LK XX
LSIGA (S, switchable) (I, switchable ANSI only) (G, Alarm Only)
Standard Range Instantaneous
LSIC (S, switchable) (I, switchable ANSI only)
LSICA (S, switchable) (I, switchable ANSI only) (C, Alarm Only) LSIGDA 1 (S, G, A switchable) (I, switchable ANSI only) LSIGCDA 1 (S, G, C, A all switchable) (I, switchable ANSI only)
EntelliGuard ™ G ANSI/UL OC Protection
LSH (S, switchable) (I, switchable ANSI only) LSHG (S, switchable) (I, switchable ANSI only)
LSHGA (S, switchable) (I, switchable ANSI only) (G, Alarm Only)
Extended Range Adjustable Instantaneous
LSHC (S, switchable) (I, switchable ANSI only)
LSHCA (S, switchable) (I, switchable ANSI only) (C, Alarm Only) LSHGDA 1 (S, G, A switchable) (I, switchable ANSI only) LSHGCDA 1 (S, G, C, A all switchable) (I, switchable ANSI only)
NONE - (For Switch Only)
–
1 Function Combination is NOT UL Listed NOTES: L = Long Time (L, I 2 T) + Fuse Settings (I 4 T) (Fuse settings are now standard on all EntelliGuard ™ Trip Units) S = Short Time (Switchable if Instantaneous (I) protection is enabled) I = Standard Range Adjustable Instantaneous, (IOC, 2x-15x) H = Extended Range Adjustable Instantaneous, (IOC, 2x-30x), Not available in UL489 version of Entelliguard G or any Legacy CB G = Ground Fault Protection (GFP, 3-wire or 4-wire, internal summing) C = External CT for ground fault detection (AKD20 application: input from external summing CTs, used for multiple source ground fault detection.
OEM Application: Zero Sequence Input of (1A = 100%) D = Defeatable/Switchable Ground Fault NOT UL Listed A = Ground Fault, External Ground Fault, Alarm only GA = Ground Fault Alarm Only CA = External Ground Fault Alarm Only GDA, GCDA = Ground Fault Trip and Ground Fault Alarm (all switchable, Not UL Listed) Option "XX" is the only valid option when a Switch is selected in Digit 2
Digit 18 Zone Selective Interlocking (ZSI) Zone Selective Interlocking
Digit 20 Rating Plug Rating Plug
Code
Product Number GTP0150U0104 GTP0200U0204 GTP0225U0306 GTP0250U0407 GTP0300U0408 GTP0350U0408 GTP0400U0410 GTP0450U0612 GTP0500U0613 GTP0600U0616 GTP0700U0816 GTP0750U0820 GTP0800U0820 GTP0900U1020 GTP1000U1025 GTP1100U1225 GTP1200U1232 GTP1500U1640 GTP1600U1640 GTP1900U2050 GTP2000U2050 GTP2200U2550 GTP2400U2564 GTP2500U2564 GTP3000U3064 GTP3200U3264 GTP3600U4064 GTP4000U4064 GTP5000U5064 GTP6000U6064
Code
ZSI, Short time and GF; user selectable Z+IOC or HSIOC ZSI; user selectable
Z T
150 200 225 250 300 350 400 450 500 600 700 750 800 900
B C D E F G H
Blank/none X ZSI selections require Secondary Disconnect Block B and 24Vdc control power. NOTE: Option X is the only valid item when a Switch is selected in Digit 2. Digit 19 Advanced Features and Communications Advanced Features and Communications Code Reduced Energy Let Through (RELT) 1 Modbus Protocol + RELT 2 Profibus Protocol + RELT 3 Monitoring + RELT, NO communication 4 Monitoring + Relay Package + RELT 5 Monitoring+ Data Acquisition, Modbus Protocol + RELT 6 Monitoring+ Data Acquisition, Profibus Protocol + RELT 7 Monitoring + Data Acquisition, Relay Package, Profibus, RELT 8 Monitoring + Data Acquisition, Relay Package, Modbus RELT 9 None X NOTES: – All Advanced Feature selections require Secondary Disconnect Block B and 24Vdc control Power. – Option "X" is the only valid option when a Switch is selected in Digit 2. – RELT = Reduced Energy Let Through, requires dedicated input and output on the CB Monitoring = Advanced Metering. – Data Acquisition = Waveform Capture and Harmonic Analysis. – In order to output the Coil Signaling status HiFi via trip unit (Digit 12, Options B, D, F, H, K, M, P, R, T, and V) a communications package must be selected in Advanced Features (Digit 19; options 2, 3, 6, 7, 8, 9). This option requires Secondary Disconnect Block B. – In order to output the RTC contact output via Trip Unit (Digit 13; Options 3, F, J, M) a communications package must be selected in Advanced Features (Code 19/Step 16); this requires Secondary Disconnect Block B.
I
J
K
M N O Q R S U V W P
1000 1100 1200 1500 1600 1900 2000 2200 2400 2500 3000 3200 3600 4000 5000 6000
Y Z 1 2 3 4 5 6 7 8
Rating plug not required/non auto switch X NOTE: See Section 6 for further details on rating plugs and sensors. Option X is the only valid option when a Switch is selected in Digit 2.
Note: See EntelliGuard ™ G Circuit Breaker Configurator for pricing. Contact a sales representative for configurator.