— EntelliGuard ™ G circuit breaker EntelliGuard ™ G circuit breaker nomenclature
Digit 6 Mounting Designation
Mounting
Poles
Code
3
1 2 3 4 5 6
Drawout
4, right
4, left
OEM
3
Stationary
4, right
4, left
Drawout
3 3
D
ABB Equipment
Stationary
F
NOTE: Right, Left indicates the location of the fourth pole, typically used to switch the Neutral. NOTE: 800A Envelope 2 (E, M Ratings) are not available in 4-pole design. NOTE: P frame available as 3-pole only
Digit 7 Spring Charge Motor Spring Charge Motor Electrically Operated (EO)
Digit 9 Shunt Trip Extended Range Shunt Trip (ANSI/UL) 4
Code
Code
24/30Vdc
A B C D E F G H
24Vdc
M
48Vdc 60Vdc 72Vdc 250Vdc 48Vac 120Vac 240Vac 277Vac
48Vac/dc 70-72Vdc
P
Q
DC
110/125Vdc; 120Vac
R S T V
110/130Vdc
208Vac
220Vdc; 240Vac 250Vdc; 277Vac
Blank/none X 4 The Extended Range Shunt Trip is specifically intended and required for UL ANSI Ground Fault applications. The pick up range is 55-110% of the ST coil voltage. When a motor is selected from the Spring Charging Motor (Digit 7) a Shunt Trip must be selected. SELECT ONE DEVICE ONLY.
AC
J
K
Blank/None 1 X 1 An "X" (Blank/None) denotes a Manually Operated device (MO) Spring Charge Contact, GSCC1, included with all Motor Operators. NOTE: When a Spring Charging Motor is selected, a Closing Device must be selected from Closing Devices for Digit 8, and a Shunt Trip Device must be selected from Shunt Trip 1 Devices for Digit 9. Shunt Trip 1 with a coil voltage different from the Spring Charge Motor may be user selected. When a Motor & Spring Charge Contact is selected, the Ready To Close (RTC) (Digit 13) contact output options to the SD (Codes 1, 2, D, E, G, H, K, L) will be wired to the Spring Charge Contact location on the Secondary Disconnect Block. –
Digit 10 Under Voltage Release (UVR) UVR with Fixed Time Delay 5
Code
24Vdc 30Vdc
1 2 3 4 5 6 7 8
48Vac/dc 60-72Vdc
110/130Vdc; 120Vac
Digit 8 Closing Devices Closing Coil Type
208Vac
220Vdc; 240Vac 250Vdc; 277Vac
Code
24Vdc 30Vdc
A B C D E F G H M N
Blank/none X 5 The UVR Shunt Trip with Fixed Time Delay is specifically intended for applications where a delay period ('ride-through') is required due to potential voltage events. The design delays are 50msec when system voltage drops to 50% and 20 msec when system voltage drops below 50%. An optional External UVR Time Delay Module is available in a 1 - 3sec delay. SELECT ONE DEVICE ONLY.
48Vac/dc 60-72Vdc
Closing Coil (CC) 2
110Vdc/130Vdc; 120Vac
208Vac
220Vdc; 240Vac 250Vdc; 277Vac
24Vdc 30Vdc
48Vac/dc 60-72 Vdc
P
Command Operated Closing Coil (CCC) 3
Q
110Vdc/130Vdc; 120Vac
R S T
208Vac
220Vdc; 240Vac
Blank/None X 2 The Closing Coil (CC) permits either local or remote release of the spring charged closing mechanism by electrical operation. 3 The Command Operated Closing Coil (CCC) includes an additional anti-pumping safety feature to ensure that the electrical closing signal must be released before further closure is attempted, a shut off is initiated if the closing signal is maintained. NOTE: Manual button through breaker cover is included as standard assembly. NOTE: When a Spring Charging Motor is selected (Digit 7), a Closing Device must be selected from Closing Devices for Digit 8, and a Shunt Trip Device must be selected from Shunt Trip 1 Devices for Digit 9. SELECT ONE DEVICE ONLY. –