BuyLog Flippingbook JULY 2025
LOAD CENTERS, METER COMBOS, SINGLE SOCKET METERING, RESIDENTIAL CIRCUIT BREAKERS, AND SMART PANEL, BUYLOG SECTION 1
1-11
— ReliaHome P-Series+ load centers
P-Series+ main lug convertible to main circuit breaker, NEMA 1 indoor Main ampere rating 1 pole, 1” spaces Max single pole circuits Front type Replacement front ordering code 1
Main wire size (AWG/kcmil) Cu-Al
Equipment ground kit Ordering code 2
125
16
32
Combination
PFCC1612
#6 – 2/0
Factory installed TGK12 & TNLK20. Order additional TGK12 or TGK24 separately if needed. Factory installed TGK24 & TNLK20. Order additional TGK12 or TGK24 separately if needed. Factory installed TGK24 & TNLK20. Order additional TGK12 or TGK24 separately if needed. Factory installed TGK24 & TNLK20. Order additional TGK12 or TGK24 separately if needed. Factory installed TGK12 & TNLK20. Order additional TGK12 or TGK24 separately if needed. Factory installed TGK24 & TNLK20. Order additional TGK12 or TGK24 separately if needed. Factory installed TGK24 & TNLK20. Order additional TGK12 or TGK24 separately if needed. Factory installed TGK24 & TNLK20. Order additional TGK12 or TGK24 separately if needed. Factory installed TGK42 & TNLK20. Order additional TGK12 or TGK42 separately if needed. Factory installed TGK42 & TNLK20. Order additional TGK12 or TGK42 separately if needed. Factory installed TGK12 & TNLK20. Order additional TGK12 or TGK24 separately if needed. Factory installed TGK24 & TNLK20. Order additional TGK12 or TGK24 separately if needed. Factory installed TGK24 & TNLK20. Order additional TGK12 or TGK24 separately if needed. Factory installed TGK24 & TNLK20. Order additional TGK12 or TGK24 separately if needed. Factory installed TGK12 & TNLK20. Order additional TGK12 or TGK24 separately if needed. Factory installed TGK24 & TNLK20. Order additional TGK12 or TGK24 separately if needed. Factory installed TGK24 & TNLK20. Order additional TGK12 or TGK24 separately if needed. Factory installed TGK24 & TNLK20. Order additional TGK12 or TGK24 separately if needed. Factory installed TGK42 & TNLK20. Order additional TGK12 or TGK42 separately if needed. Factory installed TGK42 & TNLK20. Order additional TGK12 or TGK42 separately if needed. Factory installed TGK12 & TNLK20. Order additional TGK12 separately if needed. Factory installed TGK24 & TNLK20. Order additional TGK12 or TGK24 separately if needed. Factory installed TGK24 & TNLK20. Order additional TGK12 or TGK24 separately if needed. Factory installed TGK24 & TNLK20. Order additional TGK12 or TGK24 separately if needed. Factory installed TGK24 & TNLK20. Order additional TGK12 or TGK24 separately if needed. Factory installed TGK42 & TNLK20. Order additional TGK12 or TGK42 separately if needed. Factory installed TGK42 & TNLK20. Order additional TGK12 or TGK42 separately if needed Two (2) factory installed TGK32 and one (1) TNLK20. Order additional TGK12 or TGK32 separately if needed.
PCC1612
PFCC2012
#6 – 2/0
PCC2012
20
40
Combination
PFCC2412
#6 – 2/0
PCC2412
24
48
Combination
PFCC3012
#6 – 2/0
PCC3012
30
60
Combination
PFCC1615
#6 – 250
PCC1615
150
16
32
Combination
PFCC2015
#6 – 250
PCC2015
20
40
Combination
PFCC2020
#6 – 250
PCC2020
200
20
40
Combination
PFCC3020
#6 – 250
PCC3020
30
60
Combination
PFCC4020
#6 – 250
PCC4020
40
80
Combination
PFCC4022
#1 – 300
PCC4022
225
40
80
Combination
P-Series+ main lug convertible to main circuit breaker, NEMA 1 indoor white Main ampere rating 1 pole, 1” spaces Max single pole circuits Front type Replacement front ordering code 1
Main wire size (AWG/kcmil) Cu-Al
Equipment ground kit Ordering code 2
#6 – 2/0
125
16
32
Combination
PFCC1612W
PCC1612W
#6 – 2/0
20
40
Combination
PFCC2012W
PCC2012W
#6 – 2/0
24
48
Combination
PFCC2412W
PCC2412W
#6 – 2/0
30
60
Combination
PFCC3012W
PCC3012W
#6 – 250
150
16
32
Combination
PFCC1615W
PCC1615W
#6 – 250
20
40
Combination
PFCC2015W
PCC2015W
#6 – 250
200
20
40
Combination
PFCC2020W
PCC2020W
#6 – 250
30
60
Combination
PFCC3020W
PCC3020W
#6 – 250
40
80
Combination
PFCC4020W
PCC4020W
#1 – 300
225
40
80
Combination
PFCC4022W
PCC4022W
P-Series+ main lug convertible to main circuit breaker, NEMA 3R outdoor Main ampere rating 1 pole, 1” spaces Max single pole circuits Front type Replacement front ordering code 1
Main wire size (AWG/kcmil) Cu-Al
Equipment ground kit Ordering code 2
125
16
32
–
#6 – 2/0
PCC1612R
–
20
40
–
#6 – 2/0
PCC2012R
–
24
48
–
#6 – 2/0
PCC2412R
–
200
20
40
–
#6 – 250
PCC2020R
–
30
60
–
#6 – 250
PCC3020R
–
40
80
–
#6 – 250
PCC4020R
–
225
40
80
–
#1 – 300
PCC4022R
–
60
120
–
#1 – 300
PCC6022R
–
1 All ABB ReliaHome load centers come with the front included in the box. A replacement front is only needed if one is damaged or lost. 2 For main breaker conversion utilize THQMVXXXF for 150A-225A MLO load centers and THQMHXXXF for 125A MLO load centers. Please see main circuit breaker section of the Buylog for more details.
Made with FlippingBook Learn more on our blog