BuyLog Flippingbook JAN 2026
LOAD CENTERS, METER COMBOS, AND RESIDENTIAL CIRCUIT BREAKERS, BUYLOG SECTION 1
1-9
— ReliaHome P-Series load centers
P-Series main circuit breaker, NEMA 1 indoor Main ampere rating 1 pole, 1” spaces Max single pole circuits
Replacement front ordering code 2
Main wire size (AWG/kcmil) Cu-Al
Front type
Equipment ground kit Ordering code 1
100
16 20 30 24 24 30 16 20 30 40 20 30 30 40 40 60 40 16 20 30 24 30 16 20 30 40 20 30 40 60 40 16 16 20 20 24 30 08 20 30 08 20 20 30 40 60
32 40 60 48 48 60 32 40 60 80 40 60 60 80 80
Combination Combination Combination Combination Combination Combination Combination Combination Combination Combination Combination Combination Combination Combination Combination Combination Combination Combination Combination Combination Combination Combination Combination Combination Combination Combination Combination Combination Combination Combination Combination
PFAM1610 PFAM2010 PFAM3010 PFAM2412 PFAM2412 PFAM3012
#4 – 1/0 #4 – 1/0 #4 – 1/0 #2 – 2/0 #2 – 2/0 #2 – 2/0
TGK12/TGK24 (order separately) TGK12/TGK24 (order separately) TGK12/TGK24 (order separately) TGK12/TGK24 (order separately) TGK12/TGK24 (order separately) TGK12/TGK24 (order separately) TGK12/TGK24 (order separately) TGK12/TGK24 (order separately) TGK12/TGK42 (order separately) TGK12/TGK24 (order separately) TGK12/TGK24 (order separately) Factory installed TGK24
PAM1610 PAM2010 PAM3010 PAM2412 PAM2412G PAM3012 PAM1615 PAM2015 PAM3015 PAM4015 PAM2020 PAM3020 PAM3020G PAM4020 PAM4020G PAM6020 PAM4022 PAM1610W PAM2010W PAM3010W PAM2412W PAM3012W PAM1615W PAM2015W PAM3015W PAM4015W PAM2020W PAM3020W PAM4020W PAM6020W PAM4022W
125
150
PFAM1615 #1 – 3/0 Cu; 2/0 - 3/0 Al PFAM2015 #1 – 3/0 Cu; 2/0 - 3/0 Al PFAM3015 #1 – 3/0 Cu; 2/0 - 3/0 Al PFAM4015 #1 – 3/0 Cu; 2/0 - 3/0 Al PFAM2020 #1 – 250 Cu; 2/0 - 250 Al PFAM3020 #1 – 250 Cu; 2/0 - 250 Al PFAM3020 #1 – 250 Cu; 2/0 - 250 Al PFAM4020 #1 – 250 Cu; 2/0 - 250 Al PFAM4020 #1 – 250 Cu; 2/0 - 250 Al PFAM6020 #1 – 250 Cu; 2/0 - 250 Al PFAM4022 #1 – 300 Cu; 2/0 - 300 Al
200
Factory installed TGK24
TGK12/TGK42 (order separately)
Factory installed TGK42
TGK12/TGK32 (order separately) TGK12/TGK42 (order separately)
120
225
80
P-Series main circuit breaker, NEMA 1 indoor white Main ampere rating 1 pole, 1” spaces Max single pole circuits Front type
Replacement front ordering code 2
Main wire size (AWG/kcmil) Cu-Al
Equipment ground kit Ordering code 1
100
32 40 60 48 60 32 40 60 80 40 60 80
PFAM1610W PFAM2010W PFAM3010W PFAM2412W PFAM3012W
#4 – 1/0 #4 – 1/0 #4 – 1/0 #2 – 2/0 #2 – 2/0
TGK12/TGK24 (order separately) TGK12/TGK24 (order separately) TGK12/TGK24 (order separately) TGK12/TGK24 (order separately) TGK12/TGK24 (order separately) TGK12/TGK24 (order separately) TGK12/TGK24 (order separately) TGK12/TGK24 (order separately) TGK12/TGK42 (order separately) TGK12/TGK24 (order separately) TGK12/TGK24 (order separately) TGK12/TGK42 (order separately) TGK12/TGK32 (order separately) TGK12/TGK42 (order separately)
125
PFAM1615W #1 – 3/0 Cu; 2/0 - 3/0 Al PFAM2015W #1 – 3/0 Cu; 2/0 - 3/0 Al PFAM3015W #1 – 3/0 Cu; 2/0 - 3/0 Al PFAM4015W #1 – 3/0 Cu; 2/0 - 3/0 Al PFAM2020W #1 – 250 Cu; 2/0 - 250 Al PFAM3020W #1 – 250 Cu; 2/0 - 250 Al PFAM4020W #1 – 250 Cu; 2/0 - 250 Al PFAM6020W #1 – 250 Cu; 2/0 - 250 Al PFAM4022W #1 – 300 Cu; 2/0 - 300 Al
150
200
120
225
80
P-Series main circuit breaker, NEMA 3R outdoor Main ampere rating 1 pole, 1” spaces Max single pole circuits
Replacement front ordering code 2
Main wire size (AWG/kcmil) Cu-Al
Front type
Equipment ground kit Ordering code 1
100
32 32 40 40 48 60 16 40 60 16 40 40 60 80
– – – – – – – – – – – – – – –
– – – – – – – – – – – – – – –
#4 – 1/0 #4 – 1/0 #4 – 1/0
TGK12 (order separately) Factory installed TGK12
PAM1610R PAM1610RG PAM2010R PAM2012R PAM2412R PAM3012R PAM0815RFL 3 PAM0820RFL 3 PAM2020R PAM2020RG PAM3020R PAM4020R PAM6020R PAM2015R PAM3015R
TGK12/TGK24 (order separately) TGK12/TGK24 (order separately) TGK12/TGK24 (order separately) TGK12/TGK24 (order separately)
125
#2 – 2/0 Cu-Al #2 – 2/0 Cu-Al #2 – 2/0 Cu-Al
150
#1 – 3/0 Cu; 2/0 - 3/0 Al #1 – 3/0 Cu; 2/0 - 3/0 Al #1 – 3/0 Cu; 2/0 - 3/0 Al #1 – 250 Cu; 2/0 - 250 Al #1 – 250 Cu; 2/0 - 250 Al #1 – 250 Cu; 2/0 - 250 Al #1 – 250 Cu; 2/0 - 250 Al #1 – 250 Cu; 2/0 - 250 Al #1 – 250 Cu; 2/0 - 250 Al
TGK12 (order separately)
TGK12/TGK24 (order separately) TGK12/TGK24 (order separately)
200
TGK12 (order separately)
TGK12/TGK24 (order separately)
Factory installed TGK24
TGK12/TGK24 (order separately) TGK12/TGK42 (order separately) TGK12/TGK32 (order separately)
120
1 If a larger than #4 Al/Cu ground wire is needed please order ground lug kit: TNLK20. This is a single add-a-lug- that accommodates a #6-2/0 Al/Cu ground wire. 2 All ABB ReliaHome load centers come with the front included in the box. A replacement front is only needed if one is damaged or lost. 3 These outdoor main breaker load centers come with factory installed feed through lugs.
NOTE: Circuit breakers must be ordered separately. Click here.
Made with FlippingBook Annual report maker