BuyLog Flippingbook JAN 2025
LOW VOLTAGE POWER & INSULATED CASE CIRCUIT BREAKERS, BUYLOG SECTION 8
8-176
— Power Break II circuit breakers
Stationary and draw-out breaker accessories All devices UL Listed for factory or field installation except where noted.
Mechanical Operations Counter The mechanical operations counter is mounted behind the front cover of the breaker. It is viewable through a rectangular knockout window opening in the breaker cover. It is a five digit, non-resettable counter, which is actuated each time the breaker is opened by any means.
Field Installable Product Number SPCOUNTERR
Factory Installed Product Number
SPCOUNTER
Mechanical Operations Counter
Limited Access Pushbutton Cover This accessory limits access to "ON/OFF" control of a breaker to authorized personnel. The pushbutton cover accessory consists of transparent hinged covers that can be individually sealed to the limited access assembly. Both the "ON" and "OFF" buttons can be pilot drilled to allow use of a 1/8" rod to operate either one or both pushbuttons.
Field Installable Product Number SPPBCOVERR
Factory Installed Product Number
SPPBCOVER
Breaker with limited access pushbutton cover assembly installed
Hidden "ON" Button The hidden "ON" button is assembled to the mechanism behind an unlabeled, false pushbutton. Manual closing of the breaker can only be performed by means of a small diameter rod. This accessory is used to limit access to the manual "ON" control to authorized personnel.
Field Installable Product Number
Factory Installed Product Number
SPPBNONR
SPPBNON
Activating the breaker closing mechanism through the hole in the Hidden “ON” Button
Maintenance/Repair Parts Description Top Cover and Rating Labels
Product Number SPBIICOVER 1 10054335P1 10054335P2 SPBUMPERKIT SSF08TPCCR 2 SSF16TPCCR 2 SSF20TPCCR 2 SSF40TPCCMR 3 SSF40TPCCER 4 SPPBRONR TSPL
Replacement MVT Door
Replacement Powerplus Door Stop Block Kit w/Installation Tool Visible “On” Button Conversion PB1 SM FR Door Interlock/Padlock 800A PB1 to PB2 Stationary Retrofit Kit 1600A PB1 to PB2 Stationary Retrofit Kit 2000A PB1 to PB2 Stationary Retrofit Kit 2500A-4000A PB1 to PB2 Stationary Retrofit Kit 2500A-4000A PB1 to PB2 Stationary Retrofit Kit Replacement Breaker Secondary Disconnect
SPDOSD36B
1 Special handling and order entry required to preserve UL Listing of breaker. Contact Post Sale Service for additional details of special process. 2 Manually or electrically operated 3 Manually operated 4 Electrically Operated
Made with FlippingBook Ebook Creator