LOAD CENTERS, METER COMBOS, SINGLE SOCKET METERING, AND RESIDENTIAL CIRCUIT BREAKERS, BUYLOG SECTION 1

1-34

— ReliaHome generator panels

Features • Single-phase, three-wire, 120/240 V AC • Suitable for use in accordance with Article 702 of the National Electrical Code, ANSI/ NFPA 70 • Single-phase, 2 interlock 60A or 30A main breakers, 8 circuits max. • Safety and convenience when using a generator - 14,000 peak wattage, 11,520 continuous load, 48 amps at 240 volts. • Maintains power to such critical circuits as those for furnace, pump, refrigerator, lights. • Connected dual circuit breaker mechanism ensures that only one source is active at a time.

Quickly and easily connect a residential generator with the homes electrical system. It is the ideal on/off switching system that allows the homeowner to change between power provided by the electrical utility and the generator. ReliaHome main circuit breaker generator panel helps to ensure the continuous operation of critical appliances such as lighting, refrigerators, air conditioning, and water heaters.

Main circuit breaker, two interlocked, indoor (NEMA 1) enclosure, top/bottom feed Main ampere rating 1 pole, 1” spaces 2 pole, 1” spaces 1 pole, 1/2” spaces 2 pole, 1/2” spaces Total 1-pole spaces Max single pole circuits Front type Box number

Main wire size (AWG/kcmil) Cu-Al

Equipment ground kit

Ordering code TMQ830FCUGEN

30

4

2

8

4

8

8

Flush

3A

6-1

TGK12 included TGK12 included TGK12 included TGK12 included

4

2

8

4

8

8

Surface

3A

6-1

TMQ830SCUGEN

60

4

2

8

4

8

8

Flush

3A

6-1

TMQ860FCUGEN

4

2

8

4

8

8

Surface

3A

6-1

TMQ860SCUGEN

Main circuit breaker, two interlocked, outdoor (NEMA 3R) enclosure, top feed Main ampere rating 1 pole, 1” spaces 2 pole, 1” spaces 1 pole, 1/2” spaces 2 pole, 1/2” spaces Total 1-pole spaces Box number

Main wire size (AWG/kcmil) Cu-Al

Equipment ground kit

Ordering code

30 60

4 4

2 2

8 8

4 4

8 8

R2A R2A

6-1 6-1

TGK12 included TMQ830RCUGEN TGK12 included TMQ860RCUGEN

Twist lock power inlets Receptacles

Amps

Volts

Ordering code

L14-20 L14-30 CS637

20 30 50

120/240 120/240 120/240

T020N T030N T050N

NOTE: Circuit breakers must be ordered separately. Click here.

Made with FlippingBook Online newsletter creator