METERING, BUYLOG SECTION 2
2-21
— ReliaMod® modular metering Main pull box modules 1,2,3,4
MAIN PULL BOX MODULE: 1-PHASE 3 WIRE 120/240VAC (HORIZONTAL CROSS BUS NOT INCLUDED) Main ampere rating kAIC Wire entry Incoming line lugs per phase & neutral (AWG/kcmil Cu/Al) Outgoing load lugs per phase & neutral (AWG/kcmil Cu/Al) Enclosure
Ordering code
(1) 250-750 kcmil or (2) 3/0-250 kcmil
N3R Outdoor
400
100
Bottom
Landing pad has provisions for double hole lugs up to (1) 750 kcmil Cu/Al. Lugs not included, to be provided by others. Landing pad has provisions for double hole lugs up to (2) 750 kcmil Cu/Al. Lugs not included, to be provided by others. Landing pad has provisions for double hole lugs up to (3) 750 kcmil Cu/Al. Lugs not included, to be provided by others.
RMM1P4R
(2) 250-750 kcmil or (4) 3/0-250 kcmil
RMM1P8R
800
(4) 250-750 kcmil or (8) 3/0-250 kcmil
RMM1P12R
1200
400A Pull Box Module: RMM3P4R
MAIN PULL BOX MODULE: 3-PHASE 4 WIRE 208Y/120VAC OR 3-PHASE 4 WIRE 120/240VAC DELTA HI-LEG (HORIZONTAL CROSS BUS NOT INCLUDED) Main ampere rating kAIC Wire entry Incoming line lugs per phase & neutral (AWG/kcmil Cu/Al) Outgoing load lugs per phase & neutral (AWG/kcmil Cu/Al) Enclosure
Ordering code
(1) 250-750 kcmil or (2) 3/0-250 kcmil
N3R Outdoor
400
100
Bottom
Landing pad has provisions for double hole lugs up to (1) 750 kcmil Cu/Al. Lugs not included, to be provided by others. Landing pad has provisions for double hole lugs up to (2) 750 kcmil Cu/Al. Lugs not included, to be provided by others. Landing pad has provisions for double hole lugs up to (3) 750 kcmil Cu/Al. Lugs not included, to be provided by others.
RMM3P4R
(2) 250-750 kcmil or (4) 3/0-250 kcmil
RMM3P8R
800
(4) 250-750 kcmil or (8) 3/0-250 kcmil
RMM3P12R
1200
800A Pull Box Module: RMM3P8R
Main pull box module dimensions
MAIN PULL BOX MODULE: 1-PHASE 3 WIRE 120/240VAC Main ampere rating kAIC Wire entry W (in)
H (in) 43.17 50.46 54.59
D (in)
Ordering code
400 800
100
Bottom
16.80 24.86 32.98
7.70
RMM1P4R RMM1P8R RMM1P12R
11.32 11.32
1200
MAIN PULL BOX MODULE: 3-PHASE 4 WIRE 208Y/120VAC OR 3-PHASE 4 WIRE 120/240VAC DELTA HI-LEG (HORIZONTAL CROSS BUS NOT INCLUDED) Main ampere rating kAIC Wire entry W (in) H (in) D (in) Ordering code 400 100 Bottom 16.80 43.17 7.70 RMM3P4R 800 24.86 50.46 11.32 RMM3P8R 1200 32.98 54.59 11.32 RMM3P12R ¹ Pull boxes do not come with horizontal bussing to directly connect to a main section or meter stacks as they are for lug in, lug out applications. Pull boxes include a line side lug landing pad (lugs not included) and load side mechanical lugs. This can be useful for certain utilities that prefer to land their own cables in a separate enclosure and not directly on the line side of a main breaker. ² 400A and 800A pull box models conform to EUSERC drawings 343 and 347. The 1200A pull box models do not currently meet EUSERC requirements. ³ Limited to the lowest marked short circuit rating of the main and meter modules used. ⁴ Please click on any specific ReliaMod® ordering code with a hyperlink to be taken to the respective outline drawing/spec sheet for the product to view additional technical details.
1200A Pull Box Module: RMM3P12R