BuyLog Flippingbook APR 2026

SAFETY SWITCHES AND AC DISCONNECTS, BUYLOG SECTION 4

4-18

— Heavy duty safety switches

DC rated NEMA types 1 and 3R - 600Vdc N

N

Ordering code

Auxiliary contact kits

N

N

NEMA Type 1 indoor

NEMA Type 3R outdoor Ground kit

Standard fuse class

Class J fuse kit

Class R fuse rejection kit 1

Amperage rating

Neutral kit

SPDT

DPDT

N

N

Fusible / 2 pole / 2 wire N

N

30 60

TH2261DC TH2262DC TH2263DC

TH2261RDC TH2262RDC TH2263RDC

TGL1

TNI62

H, J, and R

Move load block 3

TRK16B THAUX61S THAUX64D

TNIA62 TNIA63

TRK26A TRK46A

- -

100

TNG3

Non-fusible / 2 pole / 2 wire

30 60

THN2261DC THN2261RDC THN2262DC THN2262RDC THN2263DC THN2263RDC

TGL1

TNI62

THAUX61S THAUX64D

TNIA62 TNIA63

- -

100

TNG3

DC rated NEMA types 4X and 5/12 - 600Vdc N

N

Ordering code

Auxiliary contact kits

N

N

NEMA Type 4X stainless steel

NEMA Type 5/12 indoor Ground kit

Standard fuse class

Class J fuse kit

Class R fuse rejection kit 1

Amperage rating

Neutral kit

SPDT

DPDT

N

N

Fusible / 2 pole / 2 wire

N

N

30 60

TH2261SSDC TH2262SSDC TH2263SSDC

TH2261JDC TH2262JDC TH2263JDC

Factory installed

TNIJ61 TNIJ62

H, K, J and R H, K, J and R

Move load block 3 Move load block 3

TRK16B THAUX61S THAUX64D

TRK26A

– –

100

TNI63

TPBRK36A

Non-fusible / 2 pole / 2 wire

30 60

THN2261SSDC THN2261JDC THN2262SSDC THN2262JDC THN2263SSDC THN2263JDC

Factory installed

TNIJ61

THAUX61S THAUX64D

TNIJA62

– –

100

TNIJ63

Interlocked receptacle switches - 600Vac

Auxiliary contact kits

N

N

Ordering code

NEMA Type 1 indoor

NEMA Type 3R outdoor Receptable

Ground kit

Neutral kit

Standard fuse class

Class J fuse kit

Class R fuse rejection kit 1

Amperage rating

Mating

DPDT

N

N

Fusible / 3 pole / 3 wire

TH3362JCH 2

TH3362JCHSS 2

60

Crouse Hinds

Arktite# APJ6485

Factory installed

TNIJ62

H, K, J and R

Move load– block 3

TRK26A THAUX64D

N

N

Non-fusible / 2 pole / 2 wire

THN3362JCH 2

THN3362JCHSS 2

60

Crouse Hinds

Arktite# APJ6485

Factory installed

TNIJA62

THAUX64D

N

N

1 When specifications permit only Class R fuses, these kits may be installed in the switch to deter fuses other than Class R from being installed. 2 For horsepower ratings, see switch without "CH" suffix in publication DET845 or specification sheets found on https://empower.abb.co 3 Switches may be adapted to accept Class J fuses without a kit by moving the load-block toward the switch base and remounting.