BuyLog Flippingbook APR 2026
SAFETY SWITCHES AND AC DISCONNECTS, BUYLOG SECTION 4
4-17
— Heavy duty safety switches
NEMA types 4X and 5/12 - 600Vac - fusible
N
N
Ordering code
Auxiliary contact kits
Amperage rating
NEMA Type 4X Stainless Steel
NEMA Type 5/12 Indoor
Standard fuse class
Class J fuse kit
Class T fuse kit
Class R fuse rejection kit 2
Ground kit Neutral kit
SPDT
DPDT
N
N
Fusible / 2-pole / 3-wire
800
THF3267AXZ THF3268AXZ
– –
Factory installed
Factory installed
L
–
THT7A
–
–
THAUX67
1200
N
N
Fusible / 3-pole / 3-wire
TH3361SS 3 TH3362SS 3 TH3363SS 3 TH3364SS 3
TH3361J 5 TH3362J 5 TH3363J 5 TH3364J 5
30 60
Factory installed
TNIJ61 H, K, J and R
Move loadblock 1
–
TRK16SA THAUX61S THAUX64D
N
N
TNIJ62 TNIJ63 TNIJ64
TRK26A
– – –
TPBRK36A
100 200 400
TRK46A TRK56A
THF3365AS 3 THF3365AJ 5
–
TNIJ66 or TNIJ65A750
– THAUX66DA
THF3366AS 3 THF3366AJ 5
N
N
600
–
TNIJ66
THJ6
TRK66A
–
Fusible / 3-pole / 4-wire
800
THF4367AXZ THF4368AXZ
– –
Factory installed
Factory installed
L
–
THT7A
–
–
THAUX67
1200
N
N
NEMA types 4X and 5/12 - 600Vac - Non-fusible
N
N
Ordering code
Auxiliary contact kits
Amperage rating
NEMA Type 4X Stainless Steel
NEMA Type 5/12 Indoor
Standard fuse class
Class J fuse kit
Class T fuse kit
Class R fuse rejection kit 2
Ground kit Neutral kit
SPDT
DPDT
N
N
Non-fusible / 2-pole / 3-wire
800
THN3267AXZ THN3268AXZ
– –
Factory installed
Factory installed
L
–
THT7A
–
–
THAUX67
1200
N
N
Non-fusible /3-pole / 3-wire
THN3361SS 3 THN3362SS 3 THN3363SS 3 THN3364SS 3
THN3361J 4 THN3362J 4 THN3363J 4 THN3364J 4
30 60
Factory installed
TNIJ61
–
Move loadblock 1
–
–
THAUX61S THAUX64D
N
N
TNIJA62 TNIJ63 TNIJ64
–
100 200 400
THN3365AS 3 THN3365AJ 5
–
TNIJ66 or TNIJ65A750
THAUX66DA
THN3366AS 3 THN3366AJ 5
N
N
600
–
TNIJ66
Non-fusible / 3-pole / 4-wire
800
THN4367AXZ THN4368AXZ
– –
Factory installed
Factory installed
L
–
THT7A
–
–
THAUX67
1200
N
N
1 Switches may be adapted to accept Class J fuses without a kit by moving the load-block toward the switch base and remounting. 2 When specifications permit only Class R fuses, these kits may be installed in the switch to deter fuses other than Class R from being installed. 3 Available in NEMA 4X enclosure grade 316 stainless steel. For 30–200 A, add “316” suffix. For 400–600 A, remove “AS” and add “AX” suffix. 4 Available with field-installable copper lug kit (line, load, ground) 5 For NEMA type 3R, 5, and 12 combination 30–200 A, add an R suffix. For 400–600 A, remove “AJ” suffix “AD”
Made with FlippingBook - Online Brochure Maker