2-34
— ReliaMod™ modular metering Meter stack modules - commercial
Note: Please click on any specific ReliaMod™ ordering code with a hyperlink to be taken to the respective outline drawing/spec sheet for the product to view additional technical details.
Commercial meter stacks: 225A sockets with 1200A cross bus and lever bypass
Phase Type (Factory Installed Jaw Configuration) 1-Phase in, 1-Phase out (5-Jaw)
No. of sockets
Tenant breaker provision kAIC Ringless type socket 42,50,65,100 RMS112122CHLBR
Socket amps
Special Features
225
1 2 3 4 1 2 3 4 1 2 3 4
Only accepts XT3 or XT4 tenant breakers
RMS112222CHLBR RMS112322CHLBR RMS112422CHLBR RMS212122CHLBR RMS212222CHLBR RMS212322CHLBR RMS212422CHLBR RMS312122CHLBR RMS312222CHLBR RMS312322CHLBR RMS312422CHLBR
3-Phase in, 1-Phase out (5-Jaw)
3-Phase in, 3-Phase out (7-Jaw)
Commercial meter stacks: 400A sockets with 1200A cross bus and lever bypass
Phase Type (Factory Installed Jaw Configuration) 1-Phase in, 1-Phase out (5-Jaw)
— 225A 4-Gang Lever Bypass Meter Module: RMS212422CHLBR
No. of sockets
Tenant breaker provision kAIC Ringless type socket
Socket amps
Special Features
400
1
65 kAIC XT5N (TMA) Breakers(s) Included
RMS112140CHLBRB One 400A XT5N (TMA) tenant breaker included, 65 kAIC RMS112240CHLBRB Two 400A XT5N (TMA) tenant breakers included, 65 kAIC RMS212140CHLBRB One 400A XT5N (TMA) tenant breaker included, 65 kAIC RMS212240CHLBRB Two 400A XT5N (TMA) tenant breakers included, 65 kAIC RMS312140CHLBRB One 400A XT5N (TMA) tenant breaker included, 65 kAIC RMS312240CHLBRB Two 400A XT5N (TMA) tenant breakers included, 65 kAIC
2
3-Phase in, 1-Phase out (5-Jaw)
1
2
3-Phase in, 3-Phase out (7-Jaw)
1
65 kAIC XT5N (TMA) Breaker(s) Included
2
1
42,50,65,100 RMS312140CHLBR
No breakers included, requires two XT3 or XT4 (TMF) ReliaMod™ tenant breakers, 400A max sum, metered by one socket
Meter socket tenant neutral lug and tenant ground lug summary (One lug per each socket) Socket amperage Load neutral lug (Cu/Al)
Equipment ground lug (Cu/Al)
125A 225A 400A
#14-2/0 AWG #6-300 kcmil
#14-2/0 AWG #14-2/0 AWG
(2) 2/0-500 kcmil #6-300 kcmil Note: All XT3 and XT4 tenant breakers for ReliaMod™ 225A socket meter stacks come with thermal magnetic fixed (TMF) trip units. All factory installed XT5 tenant breakers for ReliaMod™ 400A meter stacks come with thermal magnetic adjustable (TMA) trip units.
— 400A 4-Gang Lever Bypass Meter Module: RMS212240CHLBRB